Free delivery in France from 195,00 € purchase. France, Europe, overseas delivery. Tel: + 33 (0) 4.42.41.09.08

E.on 200 Neo ceramic furnace by Ugin Dental
E.on 200 Neo display screen for Ugin Dentaire ceramic furnace
E.on 200 Neo ceramic furnace by Ugin Dental
E.on 200 Neo display screen for Ugin Dentaire ceramic furnace

Ugin e.ON 200 Neo dental ceramic furnace - 7" touchscreen

  • 6.240,00 €
  • Unit price
Earn 6 loyalty points

Référence: FC01EON0006

- +
European delivery depending on destination
Secure payment by credit or debit card
Secure payment with PayPal
PayPal may offer Pay in 3 if the customer and purchase are eligible
Credit / debit card
PayPal
Bank transfer
* Instalment payment may be offered by PayPal subject to customer and purchase eligibility. Available options may vary depending on the PayPal account.
Ugin e.ON 200 Neo ceramic furnace for dental prosthetics laboratory
Brand: Ugin Dentaire SKU: FC01EON0006 7-inch touchscreen 100 programs + 100 favourites USB backup & transfer

Ugin e.ON 200 Neo ceramic furnace – 7-inch touchscreen for dental laboratories

The Ugin e.ON 200 Neo ceramic furnace is designed for dental prosthetics laboratories looking for reliable, clear and repeatable firing of modern dental ceramics.

Its 7-inch colour touchscreen, graphic cycle monitoring, automatic calibration and USB backup make daily control easier for layered, stained or glazed ceramic restorations.

Touch interface High-definition 7-inch colour screen
Programming 100 firing programs + 100 associated favourites
Visual control Colour graphic monitoring of firing cycles
Traceability USB for backup, transfer and archiving

Next-generation ceramic furnace for dental laboratories

The e.ON 200 Neo Ugin Dentaire combines hardware and software innovations developed for firing current ceramic materials. It allows precise cycle control, real-time curve visualisation and safer protocols through an intuitive interface.

The firing chamber with refractory fibres helps control thermal inertia. This stability limits differences between the displayed temperature and the temperature actually transmitted to restorations, improving shade consistency, glaze quality and final gloss.

For laboratories looking to standardise protocols, archive programs and work with a clear reading of firing cycles, the e.ON 200 Neo furnace provides a modern, coherent solution adapted to daily aesthetic production.

Key strengths of the e.ON 200 Neo

  • High-definition 7-inch touchscreen for clear and fast navigation.
  • Colour graphic monitoring of firing cycles.
  • 100 programs and 100 favourites for recurring protocols.
  • Fault detection and operating alert display.
  • Automatic calibration to stabilise results over time.
  • Optional vacuum pump according to the firing protocols used.

Interface, traceability and productivity

  • Data backup and transfer via USB port.
  • Possible use of a mouse via USB.
  • 6 available languages: FR, EN, DE, IT, ES, RU.
  • Architecture designed for fast ramps and controlled cooling.
  • Magnetic tray for safer handling of hot workpieces.
  • Simplified management of validated programs by material or protocol.

Clearer control of firing cycles

The colour graphic monitoring of the e.ON 200 Neo ceramic furnace allows the dental technician to visualise cycle progress in real time. Ramps, holding stages and cooling phases become easier to control, helping the technician better understand the behaviour of sensitive firing cycles.

This graphic display is particularly useful for laboratories working with multiple materials, several shades or several operators. Validated cycles can be stored, retrieved and backed up to maintain a consistent working method.

The combination of open programming, favourites, automatic calibration and USB archiving helps create a reliable organisation around daily ceramic firing.

Recommended commissioning

  1. Install the furnace on a stable surface with sufficient free space at the rear.
  2. Check the 230 V – 50/60 Hz power supply.
  3. Set the language, time and basic parameters.
  4. Visually check the integrity of the firing chamber.
  5. Run an empty test cycle before the first ceramic work.
  6. Start the automatic calibration procedure.

Calibration and protocol validation

The automatic calibration program supports the laboratory’s quality monitoring. After installation, it is recommended to run a calibration, then perform a reference cycle on a test ceramic before sensitive production.

Validated programs can then be saved on a USB device to maintain a stable working base. This method improves result continuity between several technicians and limits parameter variations.

Technical specifications

Product Ugin e.ON 200 Neo ceramic furnace
Brand Ugin Dentaire
Reference / SKU FC01EON0006
Equipment type Firing furnace for dental ceramics
Screen High-definition 7-inch colour touchscreen
Programs 100 programs + 100 associated favourites
Firing monitoring Colour graphic display with dual display
Calibration Automatic calibration program
Connection USB for backup, transfer and data
Languages French, English, German, Italian, Spanish, Russian
Dimensions 57 × 32 × 36 cm
Maximum power 1,850 W
Power supply 230 V – 50/60 Hz
Noise level < 70 dB(A)
Vacuum pump Not included, available as an option

Why choose a ceramic furnace with touchscreen and graphic monitoring?

In a dental prosthetics laboratory, the final quality of a ceramic restoration depends on many parameters: temperature ramp, holding time, cooling, vacuum use, positioning of the workpieces and stability of the firing chamber.

A furnace with a touchscreen and graphic monitoring makes these steps easier to read. The operator can visualise the cycle, control parameters more easily and structure repeatable working protocols.

Conventional ceramic furnace VS e.ON 200 Neo

Criteria Conventional ceramic furnace Ugin e.ON 200 Neo
Cycle reading More limited display depending on generation. Colour graphic monitoring with dual display.
Navigation Conventional controls or simpler menus. High-definition 7-inch colour touchscreen.
Program organisation Variable memory depending on model. 100 programs + 100 associated favourites.
Traceability Export sometimes limited or unavailable. Data backup and transfer via USB.
Quality control Control depends more heavily on operator habits. Automatic calibration and operating alerts.
User comfort Less visual reading. Modern, clear interface adapted to daily production.

Program organisation

Programs and favourites make it possible to build an internal library of validated cycles. The laboratory can organise parameters by material, shade, indication or type of finishing.

  • Cycles dedicated to layering firings.
  • Specific programs for stains.
  • Glazing and finishing cycles.
  • Favourites for recurring work.
  • USB backup of validated programs.

Deviation control and alerts

Fault detection and operating fault display help the technician quickly identify a potential issue. This visibility improves cycle safety and helps avoid continuing sensitive firing without control.

  • Faster reading of anomalies.
  • Better understanding of the cycle in progress.
  • Reduced parameter-setting errors.
  • Simpler documentation of quality monitoring.
  • More consistent production between operators.

Maintenance and best practices

To maintain stable firing, it is recommended to regularly check the chamber, air inlets, ventilation, connections and general condition of the furnace. A clean and properly ventilated environment helps preserve cycle consistency.

Automatic calibration should be carried out according to the laboratory’s quality protocol. Reference cycles and USB backups help maintain a reliable reference, useful in the event of variations in appearance, shade or gloss on restorations.

Delivery and included accessories

Delivery: 1 Ugin e.ON 200 Neo ceramic furnace with its magnetic tray. The vacuum pump is not included and must be ordered separately if required.

Before installation, check the available space, power supply and ventilation conditions around the unit.

Documents and resources

FAQ – Ugin e.ON 200 Neo ceramic furnace

What type of laboratory is the Ugin e.ON 200 Neo furnace intended for?

The e.ON 200 Neo is intended for dental laboratories that regularly carry out ceramic firings and want to secure their protocols. It is particularly suitable for structures looking for a modern interface, clear cycle monitoring and improved repeatability of results.

Its touchscreen, storable programs, favourites and USB export allow work to be organised more methodically, especially when several technicians use the same equipment.

Why is the 7-inch touchscreen useful in daily work?

The colour touchscreen makes parameters easier to read and programs easier to modify. It allows faster work, with intuitive navigation and more comfortable visualisation of firing cycles.

For a dental prosthetics laboratory, this ergonomics reduces unnecessary handling and improves understanding of the cycles in progress. Settings become clearer, which is particularly useful for sensitive ceramic protocols.

How does graphic monitoring improve firing control?

Graphic monitoring allows the progress of the cycle to be visualised in real time. The dental technician can control ramps, holding stages and cooling phases with greater precision.

This visual reading helps standardise results more effectively, detect deviations more quickly and document validated protocols. It also helps strengthen firing repeatability on recurring aesthetic restorations.

Is the vacuum pump included with the furnace?

No, the vacuum pump is not included with the e.ON 200 Neo furnace. It is available separately and must be selected according to the laboratory’s requirements and the firing protocols used.

For ceramic work requiring controlled vacuum firing, it is recommended to combine the furnace with a compatible pump. The choice depends on the materials, indications and ceramic manufacturers’ recommendations.

How should the furnace be maintained to keep results consistent?

It is recommended to regularly check the chamber, air inlets, ventilation and connections. Automatic calibration should be performed at regular intervals to maintain stable and repeatable firing over time.

The laboratory can also keep reference cycles and save validated programs on USB. In the event of repeated deviations in the final appearance of restorations, this method makes it easier to analyse and requalify the parameters.

A modern ceramic furnace for clearer and more repeatable protocols

The Ugin e.ON 200 Neo ceramic furnace provides a professional answer for laboratories that want better control over ceramic firings, structured programs and secure aesthetic results.

Its 7-inch touchscreen, colour graphic monitoring, automatic calibration and USB backup make it suitable for current production workflows, where cycle readability and traceability are important elements of quality control.

For a dental prosthetics laboratory looking for a reliable, ergonomic ceramic firing furnace organised around repeatability, the Ugin e.ON 200 Neo is a coherent premium solution.

Ugin e.ON 200 Neo dental ceramic furnace - 7" touchscreen
24/7 customer service

infos@massiliadental.com

Secure payments

Paypal - CB - Amex - Transfer

LIVRAISON GRATUITE

A partir de 195 € en Métropole

Warranty 1 to 3 years old

Depending on the brand of the material