Silent TS2 suction contains bi -post - Double filtration system
Référence: 2930.0050
Renfert SILENT TS2 extraction unit for 2 dental laboratory workstations
The Renfert SILENT TS2 is a dual-workstation extraction unit for dental laboratories, designed to provide stable, quiet and reliable suction performance for two workstations.
It combines a robust carbon brush motor, double filtration, automatic suction power regulation and fast maintenance. It is a relevant solution for laboratories looking to centralize extraction for two workstations without switching to EC brushless technology.
A Renfert dual-workstation extraction unit designed for dental laboratories
The SILENT TS2 meets the needs of dental laboratories that want to connect two workstations to one extraction unit while maintaining controlled noise levels, efficient filtration and simple maintenance.
Lab tip: this model is particularly useful when replacing two small individual extraction units with a cleaner, more compact and better integrated 2-workstation extraction solution.
Key advantages
- Simultaneous suction on two workstations.
- Automatic suction power regulation according to laboratory needs.
- Double filtration with class M filter.
- Optional H / HEPA filter available.
- Quiet operation with a noise level of approximately 59 dB(A).
- Long-life carbon brush motor with 1,000 hours guaranteed.
Laboratory applications
- Extraction for two dental prosthetic workstations.
- Grinding, finishing and adjustment work.
- Organization of a centralized technical workspace.
- Use under the bench or close to the workstations.
- Suitable for laboratories looking for compact, reliable and quiet extraction.
Why a dual-workstation extraction unit is useful in a dental laboratory
When several workstations are used daily for grinding, finishing or adjustments, a dedicated extraction unit helps capture fine dust at the source, reduce contamination on work surfaces and improve the overall comfort of the laboratory.
With its automatic regulation, double filtration and ability to supply two independent workstations, the Renfert SILENT TS2 is a coherent solution for laboratories looking for compact and reliable centralized extraction.
Recommended use
- Install the extraction unit under the bench or in a technical area close to the workstations.
- Connect both workstations with suitable tubing.
- Connect the unit to the correct power supply according to the selected version.
- Use the multifunction display to monitor and control operation.
- Replace the filter or motor when required to maintain suction performance.
Installation in the dental laboratory
The SILENT TS2 is designed to be installed under the bench or in a technical area in order to efficiently supply two workstations. Its compact format makes integration easier while maintaining constant extraction performance.
- Installation under a bench or in a service area.
- Connection of two independent workstations.
- Simple configuration via the multifunction display.
- Quick control of the filter, dust container and motor.
- Maintenance designed to reduce production downtime.
Technical specifications of the SILENT TS2
| Specification | Value |
|---|---|
| Use | Extraction for 2 workstations |
| Reference | 2930.0050 |
| Voltage | 220 – 240 V depending on available version |
| Frequency | 50 / 60 Hz |
| Power consumption | 1,400 W |
| Max. volumetric flow | 3,300 l/min |
| Max. vacuum | 200 hPa |
| Noise level | 59 dB(A) |
| Motor | Carbon brush motor, 3× longer service life, 1,000 h guaranteed |
| Filtration | Double filtration, class M filter, optional H / HEPA filter |
| Number of workstations | 2 independent workstations |
| Display | Multifunctional, intuitive |
| Dimensions W × H × D | 224 × 591 × 584 mm |
| Weight | 27 kg |
| Dust container capacity | 7.5 L |
| Inner tubing Ø | 45 mm |
| Outer tubing Ø | 50 mm |
Quick comparison within the Renfert range
| Model | Main use | Motor technology | Positioning |
|---|---|---|---|
| Silent Compact | Individual workstation | Carbon brush | Compact version |
| SILENT TS | 1 laboratory workstation | Carbon brush | Single-workstation unit with double filtration |
| Silent TC2 | 2 laboratory workstations | Carbon brush | Versatile dual-workstation unit |
| Silent EC2 | 2 laboratory workstations | EC / brushless | Premium version |
You may also be interested in
Delivery
- 1 Renfert SILENT TS2 extraction unit.
- Filtration components according to manufacturer configuration.
- Technical documentation and instructions for use.
- Access to Renfert spare parts and maintenance support.
Official Renfert resources
Frequently asked questions about the SILENT TS2
Can the SILENT TS2 extract from two workstations at the same time?
Yes. The Renfert SILENT TS2 is designed to operate with two workstations, making it suitable for laboratories that want to centralize extraction without multiplying individual units.
This configuration is particularly useful for grinding, finishing and adjustment areas where two technicians may need reliable suction performance at the same time.
Is the noise level suitable for an open laboratory?
Yes. With a noise level of approximately 59 dB(A), this dual-workstation extraction unit offers relatively quiet operation for its category.
This helps improve daily working comfort, especially in laboratories where several workstations, micromotors or finishing tools are used throughout the day.
Does the system use double filtration?
Yes. The SILENT TS2 is based on a double filtration system with a class M filter for effective dust control in the dental laboratory.
Depending on the laboratory configuration, an optional H / HEPA filter can also be added to improve filtration of fine particles and reinforce air quality management.
What is the difference between the SILENT TS2 and the SILENT EC2?
The SILENT TS2 uses a durable carbon brush motor, while the SILENT EC2 is equipped with EC brushless technology.
The TS2 is a solid and efficient dual-workstation solution, while the EC2 is positioned as a higher-end model for laboratories seeking even longer motor life and more intensive use.
Can the motor be replaced quickly?
Yes. Renfert designed the SILENT TS2 with fast maintenance in mind, including simplified access for motor replacement when required.
This helps reduce downtime and allows the laboratory to maintain reliable suction performance without long interruptions in daily production.
Product note: the Renfert SILENT TS2 is a particularly relevant solution for laboratories looking for a reliable, quiet, compact and easy-to-maintain 2-workstation extraction unit.