{"product_id":"berceau-cylindre-ugin-ducatron-serie-3-quattro","title":"UGIN Casting Ring Holder for Ducatron Series 3 \u0026 Quattro Induction Casting Machines","description":"\u003cdiv id=\"md-product-ugin-casting-ring-holder\"\u003e\n\n\u003c!-- ========================= HERO ========================= --\u003e\n\u003csection class=\"mdp-hero\"\u003e\n\n\u003cdiv class=\"mdp-card mdp-visual\"\u003e\n\u003cimg loading=\"lazy\" alt=\"UGIN casting ring holder for Ducatron Series 3 and Quattro induction casting machines\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/berceau-fronde-ducatron-serie-3.jpg?v=1761848184\"\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mdp-card mdp-hero-content\"\u003e\n\n\u003cp class=\"mdp-eyebrow\"\u003e\nOriginal component for dental laboratory induction casting systems\n\u003c\/p\u003e\n\n\u003ch2\u003e\nUGIN Casting Ring Holder for Ducatron Series 3 \u0026amp; Quattro Induction Casting Machines\n\u003c\/h2\u003e\n\n\u003cdiv class=\"mdp-badges\"\u003e\n\u003cdiv class=\"mdp-chip\"\u003eOriginal UGIN component\u003c\/div\u003e\n\u003cdiv class=\"mdp-chip\"\u003eDental alloy casting\u003c\/div\u003e\n\u003cdiv class=\"mdp-chip\"\u003eDucatron compatible\u003c\/div\u003e\n\u003cdiv class=\"mdp-chip\"\u003eDental laboratory\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mdp-mini-grid\"\u003e\n\n\u003cdiv class=\"mdp-mini-card\"\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e\nFON06TOL0004\n\u003c\/div\u003e\n\n\u003cdiv class=\"mdp-mini-card\"\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e\nUGIN Dental\n\u003c\/div\u003e\n\n\u003cdiv class=\"mdp-mini-card\"\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\nDucatron Series 3 \u0026amp; Quattro\n\u003c\/div\u003e\n\n\u003cdiv class=\"mdp-mini-card\"\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e\n1 unit\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eUGIN casting ring holder\u003c\/strong\u003e is an \n\u003cstrong\u003eessential mechanical component\u003c\/strong\u003e designed for \n\u003cstrong\u003eDucatron Series 3 and Quattro induction casting machines\u003c\/strong\u003e. \nIt securely stabilizes the casting ring during dental alloy melting and centrifugal casting procedures.\n\u003c\/p\u003e\n\n\u003cp\u003e\nDesigned specifically for \n\u003cstrong\u003edental laboratories\u003c\/strong\u003e, \nthis support component provides excellent mechanical stability while contributing to safe and consistent alloy casting operations.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- ========================= INTRO SEO ========================= --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\n\u003cdiv class=\"mdp-card mdp-soft\"\u003e\n\n\u003ch3\u003e\nCasting ring holder for Ducatron induction casting systems\n\u003c\/h3\u003e\n\n\u003cp\u003e\nIn a \n\u003cstrong\u003edental induction casting machine\u003c\/strong\u003e, \nthe casting ring holder plays a critical role in stabilizing and positioning the casting ring during alloy melting and centrifugal casting cycles.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThis component ensures \n\u003cstrong\u003eoptimal stability during cobalt chrome, nickel chrome and precious metal casting procedures\u003c\/strong\u003e, helping maintain accurate alloy projection and consistent casting quality.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe original UGIN model guarantees perfect compatibility with \n\u003cstrong\u003eDucatron Series 3 and Ducatron Quattro induction casting systems\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- ========================= 2 BLOCKS ========================= --\u003e\n\u003csection class=\"mdp-grid-2\"\u003e\n\n\u003cdiv class=\"mdp-card\"\u003e\n\n\u003ch3\u003e\nBenefits of the original UGIN casting ring holder\n\u003c\/h3\u003e\n\n\u003cul class=\"mdp-checks\"\u003e\n\u003cli\u003eOfficial UGIN Dental component.\u003c\/li\u003e\n\u003cli\u003eStable support of the casting ring.\u003c\/li\u003e\n\u003cli\u003ePrecise alignment during centrifugation.\u003c\/li\u003e\n\u003cli\u003eExcellent mechanical resistance.\u003c\/li\u003e\n\u003cli\u003eHigh resistance to thermal stress.\u003c\/li\u003e\n\u003cli\u003ePerfect compatibility with Ducatron systems.\u003c\/li\u003e\n\u003cli\u003eQuick installation on induction casting machines.\u003c\/li\u003e\n\u003cli\u003eDesigned for intensive dental laboratory use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"mdp-card\"\u003e\n\n\u003ch3\u003e\nFunction of the casting ring holder in an induction casting machine\n\u003c\/h3\u003e\n\n\u003cp\u003e\nDuring alloy melting procedures, the casting ring containing the investment and wax patterns must remain perfectly stabilized to ensure homogeneous projection of the molten alloy.\n\u003c\/p\u003e\n\n\u003cp\u003e\nThe \u003cstrong\u003eDucatron casting ring holder\u003c\/strong\u003e directly contributes to system stability during machine rotation and centrifugation.\n\u003c\/p\u003e\n\n\u003cp\u003e\nA worn or damaged component may cause alignment issues and negatively affect the quality of dental metal castings.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- ========================= TABLE ========================= --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\n\u003ch3 class=\"mdp-center\"\u003e\nTechnical specifications\n\u003c\/h3\u003e\n\n\u003cdiv class=\"mdp-table-wrap\"\u003e\n\n\u003ctable class=\"mdp-table\"\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eCasting ring holder for induction casting machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eFON06TOL0004\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eUGIN Dental\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eDucatron Series 3 \/ Ducatron Quattro\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSupport and stabilization of casting rings\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eDental alloy melting and casting\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eHigh-resistance metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003e1 unit available \u003cem\u003e(6 models available)\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- ========================= LAB TIPS ========================= --\u003e\n\u003csection class=\"mdp-grid-2\"\u003e\n\n\u003cdiv class=\"mdp-card mdp-soft\"\u003e\n\n\u003ch3\u003e\nDental laboratory recommendation\n\u003c\/h3\u003e\n\n\u003cp\u003e\nTo ensure optimal stability during casting procedures, it is recommended to regularly inspect the casting ring holder for signs of wear or mechanical deformation.\n\u003c\/p\u003e\n\n\u003cp\u003e\nA perfectly aligned component helps improve casting consistency and operational safety of the induction casting machine.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"mdp-card mdp-soft\"\u003e\n\n\u003ch3\u003e\nDucatron compatibility\n\u003c\/h3\u003e\n\n\u003cp\u003e\nThis component is compatible with:\n\u003c\/p\u003e\n\n\u003cul class=\"mdp-checks\"\u003e\n\u003cli\u003eDucatron Series 3.\u003c\/li\u003e\n\u003cli\u003eDucatron Quattro.\u003c\/li\u003e\n\u003cli\u003eCompatible UGIN induction casting systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\nProduct exclusively intended for professional dental laboratory use.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- ========================= RELATED PRODUCTS ========================= --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\n\u003cdiv class=\"mdp-card\"\u003e\n\n\u003ch3 class=\"mdp-center\"\u003e\nRelated products\n\u003c\/h3\u003e\n\n\u003cdiv class=\"mdp-related\"\u003e\n\n\u003ca class=\"mdp-related-card\" href=\"https:\/\/www.massiliadental.com\/en\/products\/ugin-induction-coil-ducatron-series-3-quattro-inducast\" target=\"_self\"\u003e\n\u003cimg alt=\"Ducatron Quattro induction coil\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/self-ducatron-quattro.jpg?v=1761849217\"\u003e\n\u003cspan class=\"rel-title\"\u003e\nDucatron Quattro Induction Coil\n\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003ca class=\"mdp-related-card\" href=\"https:\/\/www.massiliadental.com\/en\/products\/ducatron-quattro-induction-casting-machine-ugin-dental\" target=\"_self\"\u003e\n\u003cimg alt=\"Ducatron Quattro induction casting machine\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/fronde-a-induction-ducatron-quattro-ugin-dentaire.jpg?v=1779370491\"\u003e\n\u003cspan class=\"rel-title\"\u003e\nDucatron Quattro Induction Casting Machine\n\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003ca class=\"mdp-related-card\" href=\"https:\/\/www.massiliadental.com\/en\/collections\/fixed-stellite-alloy-verabond-wiron-biosil\" target=\"_self\"\u003e\n\u003cimg alt=\"Dental casting alloys\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/wironit-extrahard-stellite-bego.jpg?v=1769201248\"\u003e\n\u003cspan class=\"rel-title\"\u003e\nDental Casting Alloys\n\u003c\/span\u003e\n\u003c\/a\u003e\n\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- ========================= DELIVERY ========================= --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\n\u003cdiv class=\"mdp-card\"\u003e\n\n\u003ch3\u003e\nDelivery \u0026amp; packaging\n\u003c\/h3\u003e\n\n\u003cp\u003e\nDelivery includes the \n\u003cstrong\u003eoriginal UGIN casting ring holder\u003c\/strong\u003e \nfor Ducatron Series 3 or Quattro induction casting machines.\n\u003c\/p\u003e\n\n\u003cp\u003e\nComponent intended for \n\u003cstrong\u003edental laboratories\u003c\/strong\u003e \nand dental professionals.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/section\u003e\n\n\u003c!-- ========================= SPACE ========================= --\u003e\n\u003cdiv style=\"height: 28px;\"\u003e\u003c\/div\u003e\n\n\u003c!-- ========================= FAQ ========================= --\u003e\n\u003csection class=\"mdp-faq\"\u003e\n\n\u003ch3 class=\"mdp-center\"\u003e\nFrequently asked questions\n\u003c\/h3\u003e\n\n\u003cdetails\u003e\n\n\u003csummary\u003e\nWhat is the function of the casting ring holder in a Ducatron induction casting machine?\n\u003c\/summary\u003e\n\n\u003cdiv class=\"mdp-faq-content\"\u003e\n\n\u003cp\u003e\nThe casting ring holder securely stabilizes the casting ring during alloy melting and centrifugal casting procedures.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIt ensures stable and precise positioning to achieve homogeneous projection of molten dental alloys.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\n\u003csummary\u003e\nIs this casting ring holder compatible with the Ducatron Quattro?\n\u003c\/summary\u003e\n\n\u003cdiv class=\"mdp-faq-content\"\u003e\n\n\u003cp\u003e\nYes, this component is compatible with both \n\u003cstrong\u003eDucatron Series 3\u003c\/strong\u003e \nand \n\u003cstrong\u003eDucatron Quattro\u003c\/strong\u003e \nsystems.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIt is an original UGIN component specifically designed for the brand’s induction casting equipment.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\n\u003csummary\u003e\nWhy should a casting ring holder be replaced?\n\u003c\/summary\u003e\n\n\u003cdiv class=\"mdp-faq-content\"\u003e\n\n\u003cp\u003e\nOver time, thermal and mechanical stress may cause deformation or wear of the support component.\n\u003c\/p\u003e\n\n\u003cp\u003e\nReplacing the holder helps maintain optimal casting ring stability and preserves the quality of dental metal castings.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\n\u003csummary\u003e\nIs this product intended for dental clinics?\n\u003c\/summary\u003e\n\n\u003cdiv class=\"mdp-faq-content\"\u003e\n\n\u003cp\u003e\nThis product is primarily designed for \n\u003cstrong\u003edental laboratories\u003c\/strong\u003e \nequipped with UGIN induction casting systems.\n\u003c\/p\u003e\n\n\u003cp\u003e\nIt is a technical component used during dental alloy casting procedures.\n\u003c\/p\u003e\n\n\u003c\/div\u003e\n\n\u003c\/details\u003e\n\n\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"Ugin Dentaire","offers":[{"title":"Choisissez","offer_id":57751404609871,"sku":null,"price":189.95,"currency_code":"EUR","in_stock":true},{"title":"Diameter 32 mm - 1X","offer_id":55180962398543,"sku":"FON06TOL0004","price":189.95,"currency_code":"EUR","in_stock":true},{"title":"Diameter 42 mm - 42 mm","offer_id":55180962431311,"sku":"FON06TOL0005","price":189.95,"currency_code":"EUR","in_stock":true},{"title":"Diameter 52 mm - 3X","offer_id":55180962464079,"sku":"FON06TOL0006","price":189.95,"currency_code":"EUR","in_stock":true},{"title":"Diameter 67 mm - 6X","offer_id":55180962496847,"sku":"FON06TOL0007","price":189.95,"currency_code":"EUR","in_stock":true},{"title":"Diameter 82 mm - 9X","offer_id":55180962529615,"sku":"FON06TOL0008","price":189.95,"currency_code":"EUR","in_stock":true},{"title":"Diameter 92 mm - 92 mm","offer_id":55180962562383,"sku":"FON06TOL0009","price":189.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/berceau-fronde-ducatron-serie-3.jpg?v=1761848184","url":"https:\/\/www.massiliadental.com\/en\/products\/ugin-casting-ring-holder-ducatron-series-3-quattro","provider":"Massilia Dental - Fournitures Matériel Dentaire","version":"1.0","type":"link"}