{"product_id":"anodiseur-titane-implants-barres-implantaires-html","title":"Mestra 100295 titanium anodizing unit for dental implants","description":"\u003c!-- MASSILIA DENTAL STUDIO | DESIGN : MILA PREMIUM 2026 | VERSION : MDP v1.0 | PRODUCT : Mestra Titanium Anodizing Unit MTHO0010 --\u003e\n\u003cdiv id=\"md-product\" class=\"md-product mdp-product mila-premium-2026\"\u003e\n    \u003c!-- CHAPTER 1 — HERO --\u003e\n    \u003csection class=\"mdp-section mdp-hero\"\u003e\n    \u003cdiv class=\"mdp-card mdp-visual\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/anodiseur-mestra-piece.jpg?v=1781650961\" alt=\"Mestra titanium anodizing unit for colour anodizing dental implant components\" loading=\"lazy\"\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"mdp-card mdp-hero-content\"\u003e\n        \u003cdiv class=\"mdp-badges\"\u003e\n            \u003cspan class=\"mdp-chip\"\u003eBrand: Mestra\u003c\/span\u003e\u003cspan class=\"mdp-chip\"\u003eSKU: MTHO0010\u003c\/span\u003e\u003cspan class=\"mdp-chip\"\u003e10 to 80 volts\u003c\/span\u003e\u003cspan class=\"mdp-chip\"\u003eTitanium\u003c\/span\u003e\u003cspan class=\"mdp-chip\"\u003eImplant Dentistry\u003c\/span\u003e\n        \u003c\/div\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eMestra Titanium Anodizing Unit – Colour Anodizing and Surface Treatment of Dental Implant Components\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cp\u003e\n            The \u003cstrong\u003eMestra titanium anodizing unit\u003c\/strong\u003e enables \u003cstrong\u003econtrolled titanium anodization\u003c\/strong\u003e to modify the surface appearance of dental implant components and produce different colours according to the applied voltage.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            Designed for dental laboratories and implant dentistry professionals, it can be used to treat implant abutments, screws, titanium bases, implant bars and CAD\/CAM prosthetic components compatible with the anodizing process.\n        \u003c\/p\u003e\n        \u003cdiv class=\"mdp-mini-grid\"\u003e\n            \u003cdiv class=\"mdp-mini-card\"\u003e\n                \u003cstrong\u003eRapid Anodization\u003c\/strong\u003e\n                Colour anodizing in just a few seconds\n            \u003c\/div\u003e\n            \u003cdiv class=\"mdp-mini-card\"\u003e\n                \u003cstrong\u003eImplant Dentistry\u003c\/strong\u003e\n                Titanium dental implant components\n            \u003c\/div\u003e\n            \u003cdiv class=\"mdp-mini-card\"\u003e\n                \u003cstrong\u003e10 to 80 V\u003c\/strong\u003e\n                Wide voltage range for colour selection\n            \u003c\/div\u003e\n            \u003cdiv class=\"mdp-mini-card\"\u003e\n                \u003cstrong\u003eTitanium Surface\u003c\/strong\u003e\n                Stable, protective oxide layer\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 2 — INTRODUCTION --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eWhy Anodize Titanium Components Used in Implant Dentistry?\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cp\u003e\n            Titanium naturally offers excellent corrosion resistance thanks to the formation of an oxide layer on its surface.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            Anodization increases the thickness and stability of this layer through a controlled electrochemical process. This treatment changes the visual appearance of titanium without applying paint or a coloured coating.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            In dental implantology, the resulting colour can facilitate component identification, improve the visual management of implant platforms and contribute to the aesthetic integration of certain prosthetic components beneath zirconia or ceramic restorations.\n        \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 3 — TECHNOLOGY --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eColour Anodizing Technology Based on the Electrochemical Oxidation of Titanium\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cp\u003e\n            The operating principle involves applying a controlled voltage in an electrolytic bath. This electrochemical reaction forms an oxide layer whose thickness varies according to the applied voltage.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            Each oxide layer thickness produces a different colour through optical interference. This makes it possible to obtain various shades, including yellow, blue, violet and pink, depending on the selected parameters.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            The process is fast, reproducible and suited to the requirements of dental laboratories specializing in implant prosthetics, provided that the components are properly prepared, cleaned and compatible with the treatment.\n        \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 4 — APPLICATIONS --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eApplications of the Titanium Anodizing Unit in Implant Prosthetics\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cp\u003e\n            The \u003cstrong\u003eMestra MTHO0010 anodizing unit\u003c\/strong\u003e integrates into the workflows of dental laboratories producing implant-supported restorations, machined titanium components or parts requiring colour-coded identification.\n        \u003c\/p\u003e\n        \u003cdiv class=\"mdp-grid-2\"\u003e\n            \u003cdiv class=\"mdp-card\"\u003e\n                \u003ch3\u003e\n                    \u003cstrong\u003eColour Anodizing of Implant Abutments\u003c\/strong\u003e\n                \u003c\/h3\u003e\n                \u003cp\u003e\n                    Anodization allows the colour of titanium abutments to be modified, helping improve their visual integration beneath certain aesthetic restorations.\n                \u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"mdp-card\"\u003e\n                \u003ch3\u003e\n                    \u003cstrong\u003eImplant Platform Identification\u003c\/strong\u003e\n                \u003c\/h3\u003e\n                \u003cp\u003e\n                    Colour coding facilitates rapid identification of the different implant components used in dental laboratories and clinical practices.\n                \u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"mdp-card\"\u003e\n                \u003ch3\u003e\n                    \u003cstrong\u003eTreatment of Screws and CAD\/CAM Components\u003c\/strong\u003e\n                \u003c\/h3\u003e\n                \u003cp\u003e\n                    Compatible screws, titanium bases and machined components can be anodized to achieve a consistent, easily identifiable colour finish.\n                \u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"mdp-card\"\u003e\n                \u003ch3\u003e\n                    \u003cstrong\u003eDental Laboratories Specializing in Implant Prosthetics\u003c\/strong\u003e\n                \u003c\/h3\u003e\n                \u003cp\u003e\n                    The unit enables laboratories to incorporate anodization directly into their in-house production workflow without outsourcing this stage of the process.\n                \u003c\/p\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 5 — BENEFITS --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eBenefits of Titanium Anodization for Dental Laboratories\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cdiv class=\"mdp-grid-2\"\u003e\n            \u003cdiv class=\"mdp-card\"\u003e\n                \u003ch2\u003e\n                    \u003cstrong\u003eGreater Control Over Implant Components\u003c\/strong\u003e\n                \u003c\/h2\u003e\n                \u003cul\u003e\n                    \u003cli\u003eReproducible colour anodizing of titanium components.\u003c\/li\u003e\n                    \u003cli\u003eRapid visual identification of individual parts.\u003c\/li\u003e\n                    \u003cli\u003eClearer management of implant platforms.\u003c\/li\u003e\n                    \u003cli\u003eAbility to perform the treatment directly in the dental laboratory.\u003c\/li\u003e\n                    \u003cli\u003eSuitable for abutments, screws, titanium bases and implant bars.\u003c\/li\u003e\n                \u003c\/ul\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"mdp-card\"\u003e\n                \u003ch2\u003e\n                    \u003cstrong\u003eSurface Quality and Finishing\u003c\/strong\u003e\n                \u003c\/h2\u003e\n                \u003cul\u003e\n                    \u003cli\u003eFormation of a stable oxide layer.\u003c\/li\u003e\n                    \u003cli\u003eImproved corrosion resistance of titanium.\u003c\/li\u003e\n                    \u003cli\u003eAdditional protection of the treated surface.\u003c\/li\u003e\n                    \u003cli\u003eCompatibility with zirconia and ceramic restorations depending on the clinical situation.\u003c\/li\u003e\n                    \u003cli\u003eImproved aesthetic results in certain prosthetic applications.\u003c\/li\u003e\n                \u003c\/ul\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 6 — COLOUR CHART --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eColour Chart for Titanium Anodization\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cdiv class=\"mdp-full-visual-card\"\u003e\n            \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/teintier-anodisation-titane.jpg?v=1763682474\" alt=\"Titanium anodization colour chart showing the shades obtained at different applied voltages\" loading=\"lazy\"\u003e\n        \u003c\/div\u003e\n        \u003cp\u003e\n            The resulting colour depends directly on the applied voltage. Each voltage setting produces a specific oxide layer thickness and therefore a particular colour.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            This capability allows dental laboratories to standardize their procedures and reproduce consistent colours from one component to another, provided that uniform surface preparation and a stable anodizing protocol are maintained.\n        \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 7 — OPERATION --\u003e\n    \u003csection class=\"mdp-section mdp-grid-2\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eAdjustable Voltage from 10 to 80 Volts\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cp\u003e\n            The Mestra anodizing unit features an adjustable voltage range of \u003cstrong\u003e10 to 80 volts\u003c\/strong\u003e, allowing different colours to be obtained according to the selected setting.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            This adjustment enables dental laboratories to establish their own colour references and implement a reproducible in-house protocol for titanium implant components.\n        \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eRapid Colour Anodizing in Just a Few Seconds\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cp\u003e\n            The indicated anodizing time is approximately \u003cstrong\u003e5 seconds\u003c\/strong\u003e. The speed of the process makes it easy to integrate into the laboratory production workflow.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            Proper preparation remains essential: the surface must be clean, compatible with the treatment and handled correctly to achieve uniform anodization.\n        \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 8 — TECHNICAL SPECIFICATIONS --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eMestra Titanium Anodizing Unit – Technical Specifications\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cdiv class=\"mdp-table-wrap\"\u003e\n            \u003ctable\u003e\n                \u003ctbody\u003e\n                    \u003ctr\u003e\n                        \u003cth\u003e\n                            Specification\n                        \u003c\/th\u003e\n                        \u003cth\u003e\n                            Value\n                        \u003c\/th\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Product\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            Titanium Anodizing Unit\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Brand\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            Mestra\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            SKU\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            MTHO0010\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Power Supply\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            220 to 240 V - 50\/60 Hz\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Power Consumption\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            100 W\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Voltage Range\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            10 to 80 volts\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Anodizing Time\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            Approximately 5 seconds\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Dimensions\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            160 × 207 × 245 mm\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Weight\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            2.73 kg\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003e\n                            Applications\n                        \u003c\/td\u003e\n                        \u003ctd\u003e\n                            Implants, abutments, screws, titanium bases, implant bars\n                        \u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 9 — VIDEO --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eMestra Titanium Anodizing Unit – Demonstration Video\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003carticle class=\"mdp-card mdp-related-card\"\u003e\u003ca href=\"https:\/\/www.youtube.com\/embed\/c63HM9qC2-A\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/anodisateur-titane-mestra-video.jpg?v=1729713997\" alt=\"Demonstration video of the Mestra titanium anodizing unit\" loading=\"lazy\"\u003e\n        \u003ch3\u003e\n            \u003cstrong\u003eWatch the Demonstration Video\u003c\/strong\u003e\n        \u003c\/h3\u003e\n        \u003c\/a\u003e\u003c\/article\u003e\n        \u003cp\u003e\u003c\/p\u003e\n        \u003ccenter\u003eThe video demonstrates how the Mestra titanium anodizing unit operates and how compatible components are colour anodized.\u003c\/center\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 10 — RELATED PRODUCTS --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eRecommended Related Products\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cdiv class=\"mdp-grid-3\"\u003e\n            \u003carticle class=\"mdp-card mdp-related-card\"\u003e\u003ca href=\"https:\/\/www.massiliadental.com\/en\/products\/98x10-mm-grade-5-dental-titanium-disc-cad-cam\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/disque-titane-dentaire-grade5-milaenium.jpg?v=1761848217\" alt=\"Milaenium Grade 5 dental titanium CAD\/CAM disc 98 x 10 mm\" loading=\"lazy\"\u003e\n            \u003ch3\u003e\n                \u003cstrong\u003eGrade 5 Titanium CAD\/CAM Disc – 10 mm\u003c\/strong\u003e\n            \u003c\/h3\u003e\n            \u003c\/a\u003e\u003c\/article\u003e\u003carticle class=\"mdp-card mdp-related-card\"\u003e\u003ca href=\"https:\/\/www.massiliadental.com\/en\/products\/titanium-disc-98-x-12-mm-grade-5-tc4-milaenium\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/disque-titane-dentaire-grade5-milaenium.jpg?v=1761848217\" alt=\"Milaenium Grade 5 dental titanium CAD\/CAM disc 98 x 12 mm\" loading=\"lazy\"\u003e\n            \u003ch3\u003e\n                \u003cstrong\u003eGrade 5 Titanium CAD\/CAM Disc – 12 mm\u003c\/strong\u003e\n            \u003c\/h3\u003e\n            \u003c\/a\u003e\u003c\/article\u003e\u003carticle class=\"mdp-card mdp-related-card\"\u003e\u003ca href=\"https:\/\/www.massiliadental.com\/en\/products\/grade-5-tc4-milaenium-titanium-disc-98-x-16-mm\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/disque-titane-dentaire-grade5-milaenium.jpg?v=1761848217\" alt=\"Milaenium Grade 5 dental titanium CAD\/CAM disc 98 x 16 mm\" loading=\"lazy\"\u003e\n            \u003ch3\u003e\n                \u003cstrong\u003eGrade 5 Titanium CAD\/CAM Disc – 16 mm\u003c\/strong\u003e\n            \u003c\/h3\u003e\n            \u003c\/a\u003e\u003c\/article\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 11 — DELIVERY --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eDelivery\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cp\u003e\n            Supplied: 1 \u003cstrong\u003eMestra titanium anodizing unit\u003c\/strong\u003e, 220–240 V power supply and the accessories required for treating compatible dental implant components.\n        \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 12 — FAQ --\u003e\n    \u003csection class=\"mdp-section mdp-faq\"\u003e\n    \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eFAQ – Mestra Titanium Anodizing Unit\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cdetails class=\"mdp-faq-item\"\u003e\u003csummary\u003e\u003cstrong\u003eWhich components can be anodized with this unit?\u003c\/strong\u003e\u003c\/summary\u003e\n        \u003cp\u003e\n            The unit is designed for titanium components used in implant dentistry, including abutments, screws, titanium bases, implant bars and other machined components compatible with the anodizing process.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            The treatment produces controlled colour anodization and a stable oxide layer on the surface. Before treatment, it is important to verify the component's compatibility, cleanliness and the manufacturer's recommendations.\n        \u003c\/p\u003e\n        \u003c\/details\u003e\u003cdetails class=\"mdp-faq-item\"\u003e\u003csummary\u003e\u003cstrong\u003eWhy anodize dental implant abutments?\u003c\/strong\u003e\u003c\/summary\u003e\n        \u003cp\u003e\n            Anodization produces different colours that can improve aesthetic integration beneath certain restorations and facilitate visual identification of components.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            In a dental laboratory, this colour coding also helps organize implant platforms, screws and titanium bases. The process also creates a stable oxide layer that contributes to the protection of the titanium surface.\n        \u003c\/p\u003e\n        \u003c\/details\u003e\u003cdetails class=\"mdp-faq-item\"\u003e\u003csummary\u003e\u003cstrong\u003eHow long does the anodizing process take?\u003c\/strong\u003e\u003c\/summary\u003e\n        \u003cp\u003e\n            The colour anodizing process itself is very fast and can be completed in just a few seconds, with an indicated treatment time of approximately 5 seconds depending on the applied voltage and the desired colour.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            However, component preparation remains essential. Preliminary cleaning, proper handling and adherence to the laboratory's anodizing protocol are necessary to achieve consistent and reproducible results.\n        \u003c\/p\u003e\n        \u003c\/details\u003e\u003cdetails class=\"mdp-faq-item\"\u003e\u003csummary\u003e\u003cstrong\u003eHow are different colours produced on titanium?\u003c\/strong\u003e\u003c\/summary\u003e\n        \u003cp\u003e\n            The resulting colour depends directly on the voltage applied during treatment.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            Each voltage setting produces a different oxide layer thickness, generating a specific colour through optical interference. The dental laboratory can therefore establish its own reproducible colour anodizing protocol by associating each voltage setting with an internally validated reference shade.\n        \u003c\/p\u003e\n        \u003c\/details\u003e\u003cdetails class=\"mdp-faq-item\"\u003e\u003csummary\u003e\u003cstrong\u003eDoes anodization affect the dimensions of the component?\u003c\/strong\u003e\u003c\/summary\u003e\n        \u003cp\u003e\n            The oxide layer formed during anodization is extremely thin and does not significantly alter the functional dimensions of the component.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            Implant component fit and the mechanical properties of titanium are preserved when an appropriate protocol is followed and the treated components are compatible with the process. Compliance with the implant component manufacturer's instructions remains recommended.\n        \u003c\/p\u003e\n        \u003c\/details\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n    \u003c!-- CHAPTER 13 — CONCLUSION --\u003e\n    \u003csection class=\"mdp-section\"\u003e\n    \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n        \u003ch2\u003e\n            \u003cstrong\u003eA Compact Solution for In-House Titanium Anodization in Dental Laboratories\u003c\/strong\u003e\n        \u003c\/h2\u003e\n        \u003cp\u003e\n            The \u003cstrong\u003eMestra MTHO0010 titanium anodizing unit\u003c\/strong\u003e enables dental laboratories and implant dentistry professionals to perform colour anodizing of compatible titanium components in-house.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            Its 10 to 80-volt adjustment range, rapid anodizing time and compact design make it suitable for abutments, screws, titanium bases, implant bars and CAD\/CAM components requiring a reproducible colour finish.\n        \u003c\/p\u003e\n        \u003cp\u003e\n            For dental laboratories looking to standardize their titanium anodizing protocols, improve the visual identification of components and maintain full control over surface treatment, the Mestra anodizing unit offers a professional solution that can be easily integrated into the production workflow.\n        \u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Mestra","offers":[{"title":"Default Title","offer_id":49941326102863,"sku":"100295","price":839.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/anodiseur-pour-piece-titane-mestra.jpg?v=1781650659","url":"https:\/\/www.massiliadental.com\/en\/products\/mestra-titanium-anodizing-unit-100295","provider":"Massilia Dental - Fournitures Matériel Dentaire","version":"1.0","type":"link"}