{"product_id":"laveuse-polymeriseuse-extreme-magic-18-mestra-html","title":"Mestra Extreme E2 dental flask Boil-Out \u0026 Denture polymerization unit","description":"\u003c!-- MASSILIA DENTAL STUDIO | DESIGN: MILA PREMIUM 2026 | VERSION: MDP v1.0 | PRODUCT: Mestra Extreme E2 --\u003e\n\u003cdiv id=\"md-product\" class=\"md-product mdp-product mila-premium-2026\"\u003e\n\n\u003c!-- CHAPTER 1 — HERO --\u003e\n\u003csection class=\"mdp-section mdp-hero\"\u003e\n  \u003cdiv class=\"mdp-card mdp-visual\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/laveuse-2.jpg?v=1781733821\" alt=\"Mestra Extreme E2 dental flask washer and polymerization unit for denture wax boil-out and acrylic resin curing\" loading=\"lazy\"\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"mdp-card mdp-hero-content\"\u003e\n    \u003cdiv class=\"mdp-badges\"\u003e\n      \u003cspan class=\"mdp-chip\"\u003eBrand: Mestra\u003c\/span\u003e\n      \u003cspan class=\"mdp-chip\"\u003eSKU: 080063\u003c\/span\u003e\n      \u003cspan class=\"mdp-chip\"\u003eExtreme E2\u003c\/span\u003e\n      \u003cspan class=\"mdp-chip\"\u003eUp to 12 denture flasks\u003c\/span\u003e\n      \u003cspan class=\"mdp-chip\"\u003eStainless steel\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003ch2\u003e\u003cstrong\u003eMestra Extreme E2 – Professional Dental Flask Boil-Out Washer and Acrylic Resin Polymerization Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eMestra Extreme E2 dental flask washer and polymerization unit\u003c\/strong\u003e is a professional laboratory machine designed to combine two essential stages of removable denture fabrication: \u003cstrong\u003edenture flask boil-out and wax elimination\u003c\/strong\u003e, followed by \u003cstrong\u003econtrolled polymerization of dental acrylic resins\u003c\/strong\u003e.\u003c\/p\u003e\n\n    \u003cp\u003eManufactured from \u003cstrong\u003estainless steel\u003c\/strong\u003e and featuring a loading capacity of up to \u003cstrong\u003e12 denture flasks\u003c\/strong\u003e, \u003cstrong\u003e6 pressurized water spray jets\u003c\/strong\u003e and an advanced microprocessor-controlled operating system, the Extreme E2 provides an efficient, durable and consistent solution for removable prosthodontic laboratory workflows.\u003c\/p\u003e\n\n    \u003cp\u003eBy combining flask washing and acrylic resin curing in a single programmable unit, the Mestra Extreme E2 helps dental technicians streamline production, reduce repetitive handling and maintain greater consistency throughout the denture processing workflow.\u003c\/p\u003e\n\n    \u003cdiv class=\"mdp-mini-grid\"\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003cstrong\u003eDual-function system\u003c\/strong\u003e\n        Flask boil-out and resin polymerization in one machine\n      \u003c\/div\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003cstrong\u003eLarge capacity\u003c\/strong\u003e\n        Processes up to 12 denture flasks, depending on configuration\n      \u003c\/div\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003cstrong\u003e6 water spray jets\u003c\/strong\u003e\n        Pressurized hot-water cleaning for efficient wax removal\n      \u003c\/div\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003cstrong\u003eLava E2 microprocessor\u003c\/strong\u003e\n        Automatic management of time, temperature and operating programs\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 2 — INTRODUCTION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eCombine Dental Flask Boil-Out and Acrylic Resin Polymerization in One Laboratory Machine\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eIn a professional dental laboratory, \u003cstrong\u003edenture flask boil-out\u003c\/strong\u003e and \u003cstrong\u003eacrylic resin polymerization\u003c\/strong\u003e are two essential but repetitive stages of removable prosthesis fabrication. Both require careful temperature management, consistent processing conditions and efficient organization.\u003c\/p\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eMestra Extreme E2 flask washer and polymerizer\u003c\/strong\u003e brings these operations together in a robust, programmable laboratory unit. This integrated approach improves workstation organization, reduces unnecessary handling and minimises downtime between the different stages of denture processing.\u003c\/p\u003e\n\n    \u003cp\u003eFor dental technicians, the advantages are significant: a more efficient workflow, improved operating convenience, standardized processing cycles and greater consistency when handling denture flasks.\u003c\/p\u003e\n\n    \u003cp\u003eRather than relying on separate equipment for wax elimination and resin curing, laboratories can organize both procedures around a single professional machine designed for routine prosthetic production.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 3 — DENTURE FLASK BOIL-OUT --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eEfficient Dental Flask Boil-Out with 6 Pressurized Water Spray Jets\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe integrated cleaning system uses \u003cstrong\u003e6 pressurized water spray jets\u003c\/strong\u003e to provide thorough and consistent denture flask boil-out. The combination of hot water and mechanical spray action helps soften, dislodge and remove residual wax, including from areas that are difficult to access manually.\u003c\/p\u003e\n\n    \u003cp\u003eThis \u003cstrong\u003eautomatic flask washing system\u003c\/strong\u003e improves the preparation of denture moulds before acrylic resin packing or processing, while reducing the need for repetitive manual cleaning operations.\u003c\/p\u003e\n\n    \u003cp\u003eEffective wax elimination is an important stage in removable denture fabrication because it helps prepare clean mould surfaces for subsequent resin processing.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eEasy Maintenance with a Removable Water Spray Assembly\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe spray assembly incorporates a convenient quick-removal and reinstallation system, making routine cleaning and maintenance easier.\u003c\/p\u003e\n\n    \u003cp\u003eEasy access to the spray components helps dental laboratory technicians keep the water jets unobstructed and maintain consistent cleaning performance over repeated boil-out cycles.\u003c\/p\u003e\n\n    \u003cp\u003eThis practical design is particularly valuable for laboratories processing multiple denture flasks, acrylic denture repairs and removable prosthetic cases on a regular basis.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 4 — ACRYLIC RESIN POLYMERIZATION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eDental Acrylic Resin Polymerization – Capacity for Up to 12 Denture Flasks\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eIn polymerization mode, the \u003cstrong\u003eMestra Extreme E2\u003c\/strong\u003e can accommodate up to \u003cstrong\u003e12 denture flasks\u003c\/strong\u003e, depending on their dimensions and loading arrangement.\u003c\/p\u003e\n\n    \u003cp\u003eThis generous capacity is particularly advantageous for dental laboratories manufacturing complete and partial removable dentures, performing denture repairs and relines, or processing multiple compatible prosthetic cases in batches.\u003c\/p\u003e\n\n    \u003cp\u003eThe electronic microprocessor controls the programmed heating times, temperatures and operating stages, enabling dental technicians to organize curing cycles according to the requirements of the acrylic resin being processed.\u003c\/p\u003e\n\n    \u003cp\u003eAutomated parameter management helps reduce operator-to-operator variations and supports more consistent, reproducible polymerization results.\u003c\/p\u003e\n\n    \u003cp\u003eFor laboratories with substantial removable denture workloads, the ability to process multiple flasks in a single cycle can improve throughput and reduce the number of successive curing operations.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 5 — DENTAL LABORATORY APPLICATIONS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eMestra Extreme E2 Applications in Professional Dental Laboratories\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eMestra Extreme E2\u003c\/strong\u003e is designed for dental laboratories seeking to automate and standardize the washing, wax elimination and polymerization stages associated with denture flask processing.\u003c\/p\u003e\n\n    \u003cdiv class=\"mdp-grid-2\"\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eDenture Flask Boil-Out After Wax Investing\u003c\/h3\u003e\n        \u003cp\u003eThe machine facilitates wax removal following the flasking and investing stages of denture fabrication. Hot water and pressurized spray jets help eliminate wax before acrylic resin packing.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003ePolymerization of Removable Denture Acrylic Resins\u003c\/h3\u003e\n        \u003cp\u003eThe large-capacity chamber enables several denture flasks to be processed within the same compatible polymerization cycle, improving laboratory efficiency.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eDental Laboratory Production Scheduling\u003c\/h3\u003e\n        \u003cp\u003eFive available programs help standardize everyday processing operations and manage heating, temperature holding and cycle duration.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eRoutine Professional Laboratory Production\u003c\/h3\u003e\n        \u003cp\u003eStainless steel construction and automated operation make the Extreme E2 suitable for repeated professional use in dental prosthetic laboratories.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eDenture Repairs and Relining Procedures\u003c\/h3\u003e\n        \u003cp\u003eThe generous loading capacity allows compatible repair and relining cases to be organized into batches for more efficient processing.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eComplete and Partial Removable Dentures\u003c\/h3\u003e\n        \u003cp\u003eThe Extreme E2 supports the fabrication stages of removable dental prostheses requiring denture flask wax elimination and controlled acrylic resin polymerization.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 6 — MICROPROCESSOR CONTROL --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eLava E2 Microprocessor – Advanced Control of Time, Temperature and Safety Functions\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eLava E2 microprocessor\u003c\/strong\u003e manages the principal functions of the flask washer and polymerization unit. It controls operating times, temperatures and program stages to support consistent, automated processing.\u003c\/p\u003e\n\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eElectronic control:\u003c\/strong\u003e precise management of operating times and temperatures.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003e5 available programs:\u003c\/strong\u003e flexibility for different dental laboratory processing cycles.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAudible signal:\u003c\/strong\u003e acoustic notification at the end of the selected program.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAutomatic shut-off:\u003c\/strong\u003e automatic disconnection at the end of the operating cycle.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eTriac-controlled heating:\u003c\/strong\u003e electronic regulation of the heating system.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eThermocouple monitoring:\u003c\/strong\u003e detection and indication of thermocouple failure.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eVoltage protection:\u003c\/strong\u003e electronic protection against fluctuations in the electrical supply.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eProgram memory:\u003c\/strong\u003e retention of cycle information in the event of a power interruption.\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003cp\u003eIf the electrical supply is interrupted, the controller retains the current program data. Once power is restored, the program can resume from the point at which it stopped, helping reduce the disruption caused by an unexpected power failure.\u003c\/p\u003e\n\n    \u003cp\u003eThis combination of programmable operation, electronic monitoring and integrated protective functions makes the Extreme E2 particularly useful in dental laboratories where multiple technicians operate the same equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 7 — PROGRAMMABLE FUNCTIONS --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eProgrammable Functions for Flexible Dental Laboratory Processing\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eMestra Extreme E2\u003c\/strong\u003e provides several adjustable operating parameters, allowing dental laboratories to configure cycles according to their production requirements and the processing stages involved in removable denture fabrication.\u003c\/p\u003e\n\n    \u003cul\u003e\n      \u003cli\u003eDelayed start programmable up to 180 minutes.\u003c\/li\u003e\n      \u003cli\u003eAdjustable heating ramp time.\u003c\/li\u003e\n      \u003cli\u003eAdjustable temperature holding time.\u003c\/li\u003e\n      \u003cli\u003eAdjustable water temperature up to boiling point.\u003c\/li\u003e\n      \u003cli\u003eAudible notification at the end of the cycle.\u003c\/li\u003e\n      \u003cli\u003eAutomatic shut-off.\u003c\/li\u003e\n      \u003cli\u003eIntegrated hot-water spray system for denture flask boil-out.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eDelayed Start Function for Better Laboratory Production Planning\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003edelayed start function\u003c\/strong\u003e is particularly useful for organizing daily dental laboratory production. Technicians can prepare the machine, load the denture flasks and schedule the selected program to begin at the required time.\u003c\/p\u003e\n\n    \u003cp\u003eThis feature helps laboratories plan batch processing more effectively, reduce unproductive waiting periods and standardize repetitive manufacturing operations across different technicians.\u003c\/p\u003e\n\n    \u003cp\u003eFor laboratories handling regular volumes of complete and partial dentures, programmed cycle scheduling can improve workstation organization and overall production efficiency.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 8 — PROFESSIONAL BENEFITS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eKey Benefits of the Mestra Extreme E2 for Dental Technicians\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eMestra Extreme E2 dental flask washer and polymerizer\u003c\/strong\u003e provides an integrated solution for laboratories seeking improved productivity, consistent processing conditions and reduced manual handling during removable denture fabrication.\u003c\/p\u003e\n\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eTime-saving operation:\u003c\/strong\u003e faster, better-organized denture flask boil-out and wax removal.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eReduced manual handling:\u003c\/strong\u003e fewer repetitive cleaning and processing operations.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMore consistent curing cycles:\u003c\/strong\u003e electronically controlled acrylic resin polymerization.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eGenerous loading capacity:\u003c\/strong\u003e processes up to 12 denture flasks, depending on configuration.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eStainless steel construction:\u003c\/strong\u003e suitable for humid laboratory environments and exposure to hot-water splashes.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAutomated processing:\u003c\/strong\u003e electronic management of cycle times, temperatures and programs.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEnhanced operating safety:\u003c\/strong\u003e electronic protective features and thermocouple fault detection.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAudible cycle notification:\u003c\/strong\u003e clear indication when the selected program has finished.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEasy maintenance:\u003c\/strong\u003e quick removal of the water spray assembly for cleaning.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eImproved laboratory productivity:\u003c\/strong\u003e suitable for regular production of complete and partial removable dentures.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 9 — TECHNICAL SPECIFICATIONS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eMestra Extreme E2 Dental Flask Washer and Polymerizer – Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdiv class=\"mdp-table-wrap\"\u003e\n      \u003ctable\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003cth\u003eProduct\u003c\/th\u003e\n            \u003ctd\u003eMestra Extreme E2 Dental Flask Washer and Polymerization Unit\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eBrand\u003c\/th\u003e\n            \u003ctd\u003eMestra\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eModel\u003c\/th\u003e\n            \u003ctd\u003eExtreme E2\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eMassilia Dental SKU\u003c\/th\u003e\n            \u003ctd\u003e080063\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eMain Functions\u003c\/th\u003e\n            \u003ctd\u003eDenture flask boil-out, wax elimination and acrylic resin polymerization\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003ePolymerization Capacity\u003c\/th\u003e\n            \u003ctd\u003eUp to 12 denture flasks, depending on configuration\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eFlask Washing System\u003c\/th\u003e\n            \u003ctd\u003e6 pressurized water spray jets\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eProgramming\u003c\/th\u003e\n            \u003ctd\u003e5 programs\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eDelayed Start\u003c\/th\u003e\n            \u003ctd\u003eUp to 180 minutes\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003ePower\u003c\/th\u003e\n            \u003ctd\u003e2200 + 400 W\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eExternal Dimensions\u003c\/th\u003e\n            \u003ctd\u003e635 × 405 × 450 mm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eInternal Dimensions\u003c\/th\u003e\n            \u003ctd\u003e400 × 320 × 350 mm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eWeight\u003c\/th\u003e\n            \u003ctd\u003e34 kg\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eElectrical Supply\u003c\/th\u003e\n            \u003ctd\u003e220 V\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eConstruction Material\u003c\/th\u003e\n            \u003ctd\u003eStainless steel\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 10 — OPERATING RECOMMENDATIONS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eOperating Recommendations for Consistent and Reliable Processing Cycles\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eTo achieve consistent results, the \u003cstrong\u003eMestra Extreme E2\u003c\/strong\u003e should be operated according to the dental laboratory's established procedures, the type of denture flask being processed and the acrylic resin manufacturer's instructions.\u003c\/p\u003e\n\n    \u003cp\u003eHeating times, temperatures and polymerization programs must always be appropriate for the selected material and the intended prosthetic application.\u003c\/p\u003e\n\n    \u003cdiv class=\"mdp-grid-2\"\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eGroup Compatible Denture Flasks\u003c\/h3\u003e\n        \u003cp\u003eProcess together only those denture flasks that require identical operating parameters to maintain consistent and reproducible batch conditions.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eInspect the Water Spray Jets\u003c\/h3\u003e\n        \u003cp\u003eA clean spray assembly and unobstructed water jets help preserve effective wax elimination and consistent flask washing performance.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eMonitor Program Settings\u003c\/h3\u003e\n        \u003cp\u003eAdjust cycle times, temperatures and operating stages to match the specific requirements of the laboratory's production workflow.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eMaintain the Stainless Steel Chamber\u003c\/h3\u003e\n        \u003cp\u003eRegular cleaning helps protect the stainless steel surfaces, minimise residue accumulation and maintain a cleaner working environment.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 11 — RELATED PRODUCTS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eRecommended Complementary Products\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdiv class=\"mdp-grid-3\"\u003e\n      \u003carticle class=\"mdp-card mdp-related-card\"\u003e\n        \u003ca href=\"https:\/\/www.massiliadental.com\/en\/collections\/resin-mitte-press\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/moufle-laiton-resine-laiton.jpg?v=1761848461\" alt=\"Dental denture flasks and brass moulds for acrylic resin processing in professional prosthetic laboratories\" loading=\"lazy\"\u003e\n          \u003ch3\u003e\u003cstrong\u003eDental Denture Flasks and Acrylic Resin Moulds\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003c\/a\u003e\n      \u003c\/article\u003e\n\n      \u003carticle class=\"mdp-card mdp-related-card\"\u003e\n        \u003ca href=\"https:\/\/www.massiliadental.com\/en\/collections\/cold-cure-resin-definitive-dentures\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/palaxpress-poudre-liquide-kulzer.jpg?v=1761848830\" alt=\"Cold-curing acrylic denture base resins for complete and partial removable dental prostheses\" loading=\"lazy\"\u003e\n          \u003ch3\u003e\u003cstrong\u003eAcrylic Resins for Removable Dentures\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003c\/a\u003e\n      \u003c\/article\u003e\n\n      \u003carticle class=\"mdp-card mdp-related-card\"\u003e\n        \u003ca href=\"https:\/\/www.massiliadental.com\/en\/collections\/polymax-dreve-polymerizer-photopolymerizer-acrylic-curing\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/polymax-3-rouge-dreve.jpg?v=1761858723\" alt=\"Professional dental pressure polymerizers and acrylic resin curing equipment for dental laboratories\" loading=\"lazy\"\u003e\n          \u003ch3\u003e\u003cstrong\u003eDental Pressure Polymerizers\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003c\/a\u003e\n      \u003c\/article\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 12 — DELIVERY --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eDelivery and Package Contents\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eSupplied equipment: 1 \u003cstrong\u003eMestra Extreme E2 dental flask washer and polymerization unit\u003c\/strong\u003e, with \u003cstrong\u003e220 V electrical supply\u003c\/strong\u003e, integrated stainless steel chamber, water spray system with cleaning jets and manufacturer's documentation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 13 — FAQ --\u003e\n\u003csection class=\"mdp-section mdp-faq\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eFAQ – Mestra Extreme E2 Dental Flask Washer and Polymerization Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eWhat is a dental flask washer and polymerizer used for?\u003c\/strong\u003e\u003c\/summary\u003e\n\n      \u003cp\u003eA \u003cstrong\u003edental flask washer and polymerization unit\u003c\/strong\u003e combines two important operations in removable denture fabrication: \u003cstrong\u003edenture flask boil-out\u003c\/strong\u003e and \u003cstrong\u003eacrylic resin polymerization\u003c\/strong\u003e.\u003c\/p\u003e\n\n      \u003cp\u003eThe boil-out stage removes wax from the invested denture mould before acrylic resin processing. The polymerization stage provides controlled heating to cure compatible dental acrylic resins according to the prescribed material processing protocol.\u003c\/p\u003e\n\n      \u003cp\u003eWith a dual-function machine such as the \u003cstrong\u003eMestra Extreme E2\u003c\/strong\u003e, dental laboratories benefit from programmable cycles and electronically controlled temperatures, helping improve consistency and workflow organization.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eHow many denture flasks can the Mestra Extreme E2 polymerize simultaneously?\u003c\/strong\u003e\u003c\/summary\u003e\n\n      \u003cp\u003eThe \u003cstrong\u003eMestra Extreme E2\u003c\/strong\u003e can accommodate up to \u003cstrong\u003e12 denture flasks\u003c\/strong\u003e for polymerization, depending on their dimensions and loading arrangement.\u003c\/p\u003e\n\n      \u003cp\u003eThis generous capacity is especially beneficial for dental laboratories manufacturing complete and partial removable dentures or handling regular volumes of denture repairs and relines.\u003c\/p\u003e\n\n      \u003cp\u003eProcessing multiple compatible denture flasks in one cycle helps reduce waiting periods, limit successive polymerization operations and improve daily laboratory productivity.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eWhat are the advantages of the 6 pressurized water spray jets?\u003c\/strong\u003e\u003c\/summary\u003e\n\n      \u003cp\u003eThe \u003cstrong\u003e6 pressurized water spray jets\u003c\/strong\u003e provide more uniform washing action during the denture flask boil-out stage.\u003c\/p\u003e\n\n      \u003cp\u003eHot water directed under pressure helps soften and dislodge residual wax from invested denture moulds, reducing the need for lengthy or repetitive manual cleaning.\u003c\/p\u003e\n\n      \u003cp\u003eThis integrated cleaning system improves flask preparation before acrylic resin packing and supports a more efficient denture fabrication workflow.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eWhat happens if a power failure occurs during a program?\u003c\/strong\u003e\u003c\/summary\u003e\n\n      \u003cp\u003eThe \u003cstrong\u003eLava E2 electronic controller\u003c\/strong\u003e retains the operating data of the program in progress.\u003c\/p\u003e\n\n      \u003cp\u003eIn the event of a power interruption, the most recent cycle information is stored so that the program can resume from the point at which it stopped when the electrical supply returns.\u003c\/p\u003e\n\n      \u003cp\u003eThis function helps minimise workflow disruption and reduces the risk of losing an entire programmed operation following an unexpected electrical interruption.\u003c\/p\u003e\n\n      \u003cp\u003eBefore continuing with temperature-sensitive resin processing, the operator should ensure that the interrupted cycle remains compatible with the resin manufacturer's requirements.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eWhy choose stainless steel construction for a dental flask washer?\u003c\/strong\u003e\u003c\/summary\u003e\n\n      \u003cp\u003e\u003cstrong\u003eStainless steel\u003c\/strong\u003e is particularly suitable for dental laboratory equipment exposed to hot water, steam, splashes and repeated cleaning cycles.\u003c\/p\u003e\n\n      \u003cp\u003eIt provides good corrosion resistance and facilitates routine cleaning and maintenance.\u003c\/p\u003e\n\n      \u003cp\u003eFor a combined flask washer and polymerization unit, stainless steel construction contributes to equipment durability and helps maintain a clean, practical working environment.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eIs programmable operation useful in dental laboratories with multiple technicians?\u003c\/strong\u003e\u003c\/summary\u003e\n\n      \u003cp\u003eYes. \u003cstrong\u003eProgrammable operating cycles\u003c\/strong\u003e help standardize processing procedures and reduce the risk of different technicians selecting inconsistent parameters for the same application.\u003c\/p\u003e\n\n      \u003cp\u003eThe \u003cstrong\u003eLava E2 microprocessor\u003c\/strong\u003e manages operating times, temperatures and program stages according to the selected settings.\u003c\/p\u003e\n\n      \u003cp\u003eThis automation supports more consistent results, simplifies training for new operators and helps reduce manual setting errors during routine denture flask washing and acrylic resin polymerization.\u003c\/p\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 14 — CONCLUSION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eMestra Extreme E2 – A Dual-Function Stainless Steel Unit for Efficient Dental Flask Processing\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eMestra Extreme E2\u003c\/strong\u003e is a professional \u003cstrong\u003edental flask washer and acrylic resin polymerization unit\u003c\/strong\u003e designed for laboratories seeking to combine denture flask boil-out and resin curing within a single integrated machine.\u003c\/p\u003e\n\n    \u003cp\u003eWith a capacity of up to \u003cstrong\u003e12 denture flasks\u003c\/strong\u003e, \u003cstrong\u003e6 pressurized water spray jets\u003c\/strong\u003e, \u003cstrong\u003e5 programmable operating cycles\u003c\/strong\u003e, delayed start functionality, power-interruption memory and durable \u003cstrong\u003estainless steel construction\u003c\/strong\u003e, the Extreme E2 is well suited to regular professional use.\u003c\/p\u003e\n\n    \u003cp\u003eFor dental laboratories aiming to improve productivity, standardize removable denture processing and reduce repetitive manual operations, the \u003cstrong\u003eMestra Extreme E2 dental flask washer and polymerizer\u003c\/strong\u003e offers a robust, automated and efficient solution for everyday prosthetic fabrication.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"Mestra","offers":[{"title":"Default Title","offer_id":48152265425231,"sku":"080063","price":4898.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/poli-exxtreme-e2-laveuse-mestra.jpg?v=1787586237","url":"https:\/\/www.massiliadental.com\/en\/products\/mestra-extreme-e2-dental-flask-washer-polymerizer","provider":"Massilia Dental - Fournitures Matériel Dentaire","version":"1.0","type":"link"}