{"product_id":"polymerisateur-polymax-1-120-c-dreve-html","title":"Dreve Polymax 1 dental pressure polymerizer 120°C available in red or silver","description":"\u003c!-- MASSILIA DENTAL STUDIO | DESIGN: MILA PREMIUM 2026 | VERSION: MDP v1.0 | PRODUCT: Polymax 1 Dreve 120 °C --\u003e\n\u003cdiv id=\"md-product\" class=\"md-product mdp-product mila-premium-2026\"\u003e\n\n\u003c!-- CHAPTER 1 — HERO --\u003e\n\u003csection class=\"mdp-section mdp-hero\"\u003e\n  \u003cdiv class=\"mdp-card mdp-visual\"\u003e\n    \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/polymax-1-polymerisateur-dreve.jpg?v=1766526353\" alt=\"Dreve Polymax 1 dental pressure polymerizer 120°C available in red or silver\" loading=\"lazy\"\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"mdp-card mdp-hero-content\"\u003e\n    \u003cdiv class=\"mdp-badges\"\u003e\n      \u003cspan class=\"mdp-chip\"\u003eBrand: Dreve\u003c\/span\u003e\n      \u003cspan class=\"mdp-chip\"\u003eSKU: 34281\u003c\/span\u003e\n      \u003cspan class=\"mdp-chip\"\u003ePolymax 1\u003c\/span\u003e\n      \u003cspan class=\"mdp-chip\"\u003e120 °C\u003c\/span\u003e\n      \u003cspan class=\"mdp-chip\"\u003e2.2 L chamber\u003c\/span\u003e\n    \u003c\/div\u003e\n\n    \u003ch2\u003e\u003cstrong\u003eDreve Polymax 1 120 °C – High-Temperature Dental Pressure Polymerizer for Dental Resins\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eDreve Polymax 1 120 °C\u003c\/strong\u003e is a \u003cstrong\u003ehigh-temperature pressure polymerizer\u003c\/strong\u003e designed for dental laboratories requiring reliable control over polymerization cycles involving technical dental resins, heat-curing resins, self-curing resins and materials requiring processing temperatures above 95 °C.\u003c\/p\u003e\n\n    \u003cp\u003eWith a continuously adjustable temperature of up to \u003cstrong\u003e120 °C\u003c\/strong\u003e, an operating pressure of \u003cstrong\u003e3 to 4.2 bar\u003c\/strong\u003e and a chamber capacity of approximately \u003cstrong\u003e2.2 litres\u003c\/strong\u003e, it provides greater flexibility for demanding dental resin polymerization protocols.\u003c\/p\u003e\n\n    \u003cdiv class=\"mdp-mini-grid\"\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003cstrong\u003eTemperature\u003c\/strong\u003e\n        Continuously adjustable up to 120 °C\n      \u003c\/div\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003cstrong\u003ePressure\u003c\/strong\u003e\n        3 to 4.2 bar to promote resin density\n      \u003c\/div\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003cstrong\u003eChamber\u003c\/strong\u003e\n        Convenient 2.2-litre capacity\n      \u003c\/div\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003cstrong\u003eAdvanced cycles\u003c\/strong\u003e\n        For technical resins and high-temperature protocols\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 2 — INTRODUCTION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eWhy Choose a 120 °C Dental Pressure Polymerizer?\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eA pressure polymerizer with a maximum temperature of 95 °C is suitable for many conventional dental resin applications. The \u003cstrong\u003eDreve Polymax 1 120 °C\u003c\/strong\u003e is intended for dental laboratories seeking additional temperature capacity for more advanced polymerization procedures.\u003c\/p\u003e\n\n    \u003cp\u003eIts operating range of up to \u003cstrong\u003e120 °C\u003c\/strong\u003e provides greater flexibility when processing certain technical dental resins, materials requiring higher curing temperatures or polymerization cycles demanding accurate thermal control.\u003c\/p\u003e\n\n    \u003cp\u003eThis increased versatility allows dental technicians to perform routine pressure polymerization procedures while retaining the temperature capacity required for more demanding materials.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 3 — HIGH-TEMPERATURE POLYMERIZATION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eAdvantages of High-Temperature Dental Resin Polymerization\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003e\u003cstrong\u003eHigh-temperature polymerization\u003c\/strong\u003e enables dental laboratories to perform more specialised processing protocols than conventional curing cycles. When a dental resin requires temperatures above 95 °C, the Polymax 1 120 °C provides the additional thermal capacity needed to follow the material manufacturer's recommendations.\u003c\/p\u003e\n\n    \u003cdiv class=\"mdp-grid-3\"\u003e\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eTemperature Capacity up to 120 °C\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eThe ability to reach 120 °C supports a wider range of processing protocols, particularly for selected technical dental resins and advanced thermal curing cycles.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eGreater Laboratory Versatility\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eThe same equipment can be used for conventional dental resins and more demanding applications requiring higher processing temperatures.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eImproved Cycle Control\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eThe combination of pressure, temperature and timer settings helps standardise polymerization procedures and reduce variations between successive curing cycles.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 4 — TECHNICAL DENTAL RESINS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eTechnical Dental Resins Suitable for Polymerization Cycles up to 120 °C\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003ePolymax 1 120 °C\u003c\/strong\u003e is particularly useful for dental laboratories working with several categories of dental resins. It can be used for heat-curing resins, cold-curing resins, denture repairs, denture bases, temporary restorations, relining procedures and materials requiring controlled pressure polymerization.\u003c\/p\u003e\n\n    \u003cp\u003eA temperature of 120 °C should not be used routinely for every material. It must only be selected when specified or recommended by the resin manufacturer. The main advantage of this version is its ability to accommodate higher-temperature protocols without the restrictions of a lower maximum operating temperature.\u003c\/p\u003e\n\n    \u003cdiv class=\"mdp-grid-2\"\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eHeat-Curing Dental Resins\u003c\/h3\u003e\n        \u003cp\u003eFor resins requiring controlled thermal processing, the Polymax 1 120 °C provides a stable temperature and pressure environment throughout the polymerization cycle.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eTechnical Dental Resins\u003c\/h3\u003e\n        \u003cp\u003eCertain specialised resins may require higher temperatures to achieve the hardness, dimensional stability and material properties specified by their manufacturers.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eDenture Repairs and Relining\u003c\/h3\u003e\n        \u003cp\u003ePressure helps reduce the formation of microbubbles and promotes more homogeneous, denser repaired areas, making subsequent finishing procedures easier.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eApplications Requiring Precise Finishing\u003c\/h3\u003e\n        \u003cp\u003eProperly polymerized resin is generally easier to finish and polish, helping minimise visible defects in thin or highly stressed areas.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 5 — RESIN STABILITY --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eImproving Dental Resin Stability with Polymerization Temperatures up to 120 °C\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe stability of a dental resin depends on following the correct polymerization protocol. When a material requires a higher curing temperature, equipment capable of reaching \u003cstrong\u003e120 °C\u003c\/strong\u003e allows the prescribed processing cycle to be completed without compromises caused by temperature limitations.\u003c\/p\u003e\n\n    \u003cp\u003eCombined with stable pressure, controlled temperature promotes a more homogeneous resin structure with reduced porosity and improved consistency. These advantages may become apparent during polishing, fitting and final inspection of dental prostheses.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eAdditional Thermal Capacity for Demanding Materials\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe ability to reach 120 °C allows dental technicians to follow advanced processing protocols without being restricted by a lower maximum temperature. It also provides greater flexibility for laboratories working with different resin systems.\u003c\/p\u003e\n\n    \u003cul\u003e\n      \u003cli\u003eReduced porosity through pressure polymerization.\u003c\/li\u003e\n      \u003cli\u003eGreater consistency between thermal curing cycles.\u003c\/li\u003e\n      \u003cli\u003eMore reliable processing control for technical materials.\u003c\/li\u003e\n      \u003cli\u003eStandardisation of laboratory polymerization protocols.\u003c\/li\u003e\n      \u003cli\u003eImproved surface finishing after polymerization.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 6 — APPLICATIONS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eAdvanced Applications of the Dreve Polymax 1 120 °C in Dental Laboratories\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eDreve Polymax 1 120 °C\u003c\/strong\u003e is designed for dental laboratories seeking to combine controlled pressure, elevated temperature and precise timing when performing demanding dental resin polymerization procedures.\u003c\/p\u003e\n\n    \u003cdiv class=\"mdp-grid-2\"\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eHigh-Temperature Polymerization\u003c\/h3\u003e\n        \u003cp\u003eThe 120 °C version meets the requirements of laboratories processing dental resins that need higher temperatures than conventional curing cycles.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eRemovable Dental Prostheses\u003c\/h3\u003e\n        \u003cp\u003ePressure polymerization promotes denser, more homogeneous resin denture bases that are easier to finish and polish.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eDenture Repairs and Resin Additions\u003c\/h3\u003e\n        \u003cp\u003eDuring repair procedures, pressure polymerization helps improve the consistency of the treated area while reducing internal defects.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eMulti-Purpose Dental Laboratories\u003c\/h3\u003e\n        \u003cp\u003eThe temperature range of up to 120 °C offers valuable flexibility when alternating between conventional dental resins and more specialised technical materials.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eAdvanced Polymerization Cycles\u003c\/h3\u003e\n        \u003cp\u003eAdjustable temperature settings allow technicians to follow higher-temperature processing protocols when specified in the material's technical documentation.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eAesthetic Finishing\u003c\/h3\u003e\n        \u003cp\u003eResins with reduced porosity can provide cleaner, more consistent results during trimming, grinding and polishing procedures.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 7 — 95 °C VS 120 °C --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eWhy a 120 °C Operating Temperature Provides Greater Versatility\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe main difference compared with a 95 °C version is the \u003cstrong\u003eadditional temperature capacity\u003c\/strong\u003e. This does not replace the resin manufacturer's instructions, but allows dental laboratories to perform higher-temperature cycles whenever required by the material.\u003c\/p\u003e\n\n    \u003cp\u003eThis flexibility is particularly valuable for laboratories that do not want to restrict their work to conventional dental resins. With the Polymax 1 120 °C, technicians can more easily adapt polymerization cycles to different materials while retaining the advantages of pressure curing: improved density, greater homogeneity and reduced porosity.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 8 — PROFESSIONAL BENEFITS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003ePractical Benefits for Dental Technicians\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdiv class=\"mdp-grid-3\"\u003e\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eMore Homogeneous Resin\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eThe combination of controlled pressure and temperature promotes a denser, more consistent resin structure.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eImproved Finishing Quality\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eReduced resin porosity allows more accurate trimming, grinding and polishing of dental appliances.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eGreater Operating Flexibility\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eAdjustable temperatures up to 120 °C expand the range of polymerization procedures available within the dental laboratory.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eMore Reproducible Cycles\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eThe timer and pressure monitoring system help maintain consistent processing conditions between successive curing cycles.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eSafe and Controlled Operation\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eThe automatic locking mechanism, pressure gauge and indicator light provide greater control during operation.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-card\"\u003e\n        \u003ch3\u003e\u003cstrong\u003eDreve Manufacturing Quality\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003cp\u003eDreve is an established manufacturer of materials and equipment for professional dental laboratories.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 9 — VIDEO --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2 class=\"mdp-video-title\"\u003e\u003cstrong\u003eDreve Polymax 1 Product Presentation Video\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdiv class=\"mdp-video\"\u003e\n      \u003ca href=\"https:\/\/www.youtube.com\/watch?v=7dVLE4D7rwY\"\u003e\n        \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/polymax-5-image-video.jpg?v=1773261709\" alt=\"Dreve Polymax 1 120 °C dental pressure polymerizer presentation video\" width=\"450\" loading=\"lazy\"\u003e\n      \u003c\/a\u003e\n      \u003cp\u003e\n        \u003ca href=\"https:\/\/www.youtube.com\/watch?v=7dVLE4D7rwY\"\u003e\n          \u003cspan class=\"mdp-chip\"\u003e▶ Watch the Video on YouTube\u003c\/span\u003e\n        \u003c\/a\u003e\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 10 — TECHNICAL SPECIFICATIONS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eDreve Polymax 1 120 °C Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdiv class=\"mdp-table-wrap\"\u003e\n      \u003ctable\u003e\n        \u003ctbody\u003e\n          \u003ctr\u003e\n            \u003cth\u003eProduct\u003c\/th\u003e\n            \u003ctd\u003eDreve Polymax 1 120 °C Dental Pressure Polymerizer\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eManufacturer\u003c\/th\u003e\n            \u003ctd\u003eDreve\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eModel\u003c\/th\u003e\n            \u003ctd\u003ePolymax 1\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eProduct Reference \/ SKU\u003c\/th\u003e\n            \u003ctd\u003e34281\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eEquipment Type\u003c\/th\u003e\n            \u003ctd\u003eHigh-temperature pressure polymerizer for dental resins\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eTemperature\u003c\/th\u003e\n            \u003ctd\u003eContinuously adjustable from 0 to 120 °C\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eOperating Pressure\u003c\/th\u003e\n            \u003ctd\u003eAdjustable from 3 to 4.2 bar\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eRecommended Minimum Pressure\u003c\/th\u003e\n            \u003ctd\u003eAbove 2.5 bar, depending on operating conditions\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eTimer\u003c\/th\u003e\n            \u003ctd\u003eUp to 90 minutes\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eChamber Capacity\u003c\/th\u003e\n            \u003ctd\u003eApproximately 2.2 litres\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eChamber Dimensions\u003c\/th\u003e\n            \u003ctd\u003eDiameter 160 mm – depth 110 mm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eLoading Capacity\u003c\/th\u003e\n            \u003ctd\u003eDepending on configuration: compatible articulator, Castdon flask or brass flask with clamping frames\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eEquipment Dimensions\u003c\/th\u003e\n            \u003ctd\u003eApproximately 23 × 29 × 33 cm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003ePackaging Dimensions\u003c\/th\u003e\n            \u003ctd\u003eApproximately 46 × 42 × 38 cm\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eWeight\u003c\/th\u003e\n            \u003ctd\u003eEquipment: 10 kg \/ shipping weight: 15 kg\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eElectrical Supply\u003c\/th\u003e\n            \u003ctd\u003e115 \/ 230 V – 50 \/ 60 Hz\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003ePower Consumption\u003c\/th\u003e\n            \u003ctd\u003eApproximately 450 W\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eConstruction\u003c\/th\u003e\n            \u003ctd\u003eAluminium chamber, stainless steel lid and high-strength housing\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eSafety Features\u003c\/th\u003e\n            \u003ctd\u003eAutomatic locking mechanism, pressure gauge and indicator light\u003c\/td\u003e\n          \u003c\/tr\u003e\n          \u003ctr\u003e\n            \u003cth\u003eApplications\u003c\/th\u003e\n            \u003ctd\u003eHigh-temperature dental resins, heat-curing resins, denture repairs, removable prostheses and advanced polymerization cycles\u003c\/td\u003e\n          \u003c\/tr\u003e\n        \u003c\/tbody\u003e\n      \u003c\/table\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 11 — OPERATING RECOMMENDATIONS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eOperating Recommendations for Polymerization Cycles up to 120 °C\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eA temperature of 120 °C should only be selected when required by the material being processed. The appropriate polymerization cycle must always be determined according to the dental resin, the manufacturer's instructions and the type of laboratory procedure.\u003c\/p\u003e\n\n    \u003cdiv class=\"mdp-grid-2\"\u003e\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eFollow the Resin Manufacturer's Instructions\u003c\/h3\u003e\n        \u003cp\u003eEach dental resin may require specific temperature, pressure and curing time settings. The Polymax 1 allows these parameters to be adjusted according to the prescribed processing protocol.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eMonitor Pressure During Polymerization\u003c\/h3\u003e\n        \u003cp\u003eThe pressure gauge allows technicians to verify that the operating pressure remains stable throughout the curing cycle. Consistent pressure helps minimise the formation of internal defects.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eUse Clean Water\u003c\/h3\u003e\n        \u003cp\u003eUsing clean or demineralised water can help limit mineral deposits inside the chamber and reduce scale formation, depending on local water quality.\u003c\/p\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"mdp-mini-card\"\u003e\n        \u003ch3\u003eMaintain the Lid Seal\u003c\/h3\u003e\n        \u003cp\u003eThe sealing gasket should remain clean and flexible. The use of a suitable lubricant helps preserve the sealing performance and service life of the equipment.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 12 — DOCUMENTATION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eDreve Polymax Documentation and Technical Resources\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdiv class=\"mdp-grid-2\"\u003e\n      \u003carticle class=\"mdp-card\"\u003e\n        \u003cstrong\u003eDreve Polymax Operating Instructions\u003c\/strong\u003e\n        \u003cp\u003eMultilingual operating manual covering installation, equipment settings, polymerization procedures, maintenance and safety instructions.\u003c\/p\u003e\n        \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/Polymax_5_Mode_d_emploi_ML.pdf?v=1773263921\"\u003eDownload the Dreve Polymax Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n      \u003c\/article\u003e\n\n      \u003carticle class=\"mdp-card\"\u003e\n        \u003cstrong\u003eDreve Declaration of Conformity\u003c\/strong\u003e\n        \u003cp\u003eManufacturer documentation supporting technical equipment records, traceability requirements and internal laboratory quality control procedures.\u003c\/p\u003e\n        \u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/Polymax_dreve_conformite.pdf?v=1773263920\"\u003eDownload the Dreve Declaration of Conformity\u003c\/a\u003e\u003c\/p\u003e\n      \u003c\/article\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 13 — PRODUCT COMPARISON --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eDreve Polymax 1 120 °C vs 95 °C: Which Version Should You Choose?\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003ePolymax 1 95 °C\u003c\/strong\u003e is particularly suitable for conventional dental resin applications, denture repairs and standard pressure polymerization procedures. The \u003cstrong\u003ePolymax 1 120 °C\u003c\/strong\u003e is intended for dental laboratories requiring additional thermal capacity for technical resins and advanced curing protocols.\u003c\/p\u003e\n\n    \u003cp\u003eThis distinction helps dental professionals select the appropriate equipment for their applications. The 95 °C version is primarily suited to routine dental laboratory procedures and conventional removable prosthetics, while the 120 °C version offers greater flexibility for processing materials requiring higher temperatures.\u003c\/p\u003e\n\n    \u003cp\u003e\u003ca href=\"https:\/\/www.massiliadental.com\/collections\/polymerisateur-photopolymerisateur-polymax-html\"\u003e\u003cstrong\u003eExplore the Polymax Pressure Polymerizers and Light-Curing Units Collection\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 14 — RELATED PRODUCTS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eRecommended Complementary Products\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdiv class=\"mdp-grid-3\"\u003e\n      \u003carticle class=\"mdp-card mdp-related-card\"\u003e\n        \u003ca href=\"https:\/\/www.massiliadental.com\/en\/products\/polymax-3-dreve-red-or-gray-polymerizer\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/polymax-3-rouge-dreve.jpg?v=1761858723\" alt=\"Dreve Polymax 3 95 °C dental pressure polymerizer\" loading=\"lazy\"\u003e\n          \u003ch3\u003e\u003cstrong\u003eDreve Polymax 3 95 °C\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003c\/a\u003e\n      \u003c\/article\u003e\n\n      \u003carticle class=\"mdp-card mdp-related-card\"\u003e\n        \u003ca href=\"https:\/\/www.massiliadental.com\/en\/products\/polymax-5-polymerizer-dreve\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/polymax-5-dreve-argent.jpg?v=1773265562\" alt=\"Dreve Polymax 5 dental pressure polymerizer for professional dental laboratories\" loading=\"lazy\"\u003e\n          \u003ch3\u003e\u003cstrong\u003eDreve Polymax 5\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003c\/a\u003e\n      \u003c\/article\u003e\n\n      \u003carticle class=\"mdp-card mdp-related-card\"\u003e\n        \u003ca href=\"https:\/\/www.massiliadental.com\/en\/products\/korasilon-grease-joint-polymerizer\"\u003e\n          \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/graisse-pour-thermoformeuse.jpg?v=1761850109\" alt=\"Special lubricant for Dreve Polymax sealing gaskets\" loading=\"lazy\"\u003e\n          \u003ch3\u003e\u003cstrong\u003eLubricating Grease for Polymax Sealing Gaskets\u003c\/strong\u003e\u003c\/h3\u003e\n        \u003c\/a\u003e\n      \u003c\/article\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 15 — DELIVERY --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eDelivery, Installation and Maintenance of the Dreve Polymax 1 120 °C\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eSupplied equipment: 1 \u003cstrong\u003eDreve Polymax 1 120 °C pressure polymerizer\u003c\/strong\u003e for high-temperature dental resins and advanced polymerization procedures.\u003c\/p\u003e\n\n    \u003cul\u003e\n      \u003cli\u003eInstall on a stable work surface with a suitable electrical supply.\u003c\/li\u003e\n      \u003cli\u003eConnect to a compressed air supply that meets the equipment's operating requirements.\u003c\/li\u003e\n      \u003cli\u003eOperate according to the polymerization protocols specified by the dental resin manufacturers.\u003c\/li\u003e\n      \u003cli\u003ePeriodically inspect the lid gasket, operating pressure, water level and overall chamber condition.\u003c\/li\u003e\n      \u003cli\u003eClean regularly using appropriate methods to maintain equipment performance and service life.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 16 — FAQ --\u003e\n\u003csection class=\"mdp-section mdp-faq\"\u003e\n  \u003cdiv class=\"mdp-card\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eFAQ – Dreve Polymax 1 120 °C Dental Pressure Polymerizer\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eIs the Polymax 1 120 °C more versatile than the 95 °C version?\u003c\/strong\u003e\u003c\/summary\u003e\n      \u003cp\u003eYes. The \u003cstrong\u003ePolymax 1 120 °C\u003c\/strong\u003e offers greater versatility thanks to its additional thermal capacity. It can perform conventional pressure polymerization cycles while also accommodating higher-temperature protocols required by certain technical dental resins.\u003c\/p\u003e\n      \u003cp\u003eThe 95 °C version remains suitable for standard dental laboratory applications, denture repairs and routine polymerization procedures. The 120 °C version is particularly valuable for laboratories processing multiple categories of dental resins or planning to work with specialised materials requiring more demanding thermal protocols.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eWhich dental materials may require polymerization temperatures above 95 °C?\u003c\/strong\u003e\u003c\/summary\u003e\n      \u003cp\u003eCertain \u003cstrong\u003etechnical dental resins\u003c\/strong\u003e, heat-curing materials and specialised resin systems may require processing temperatures higher than those used for conventional polymerization cycles. The correct temperature, pressure and curing time must always be determined according to the manufacturer's technical instructions.\u003c\/p\u003e\n      \u003cp\u003eThe ability to reach 120 °C does not mean that all dental resins should be processed at this temperature. The Polymax 1 120 °C simply provides the additional thermal capacity required when higher-temperature curing is specified for a particular material.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eWhy choose a dental pressure polymerizer capable of reaching 120 °C?\u003c\/strong\u003e\u003c\/summary\u003e\n      \u003cp\u003eChoosing a pressure polymerizer capable of reaching \u003cstrong\u003e120 °C\u003c\/strong\u003e provides additional flexibility for dental laboratories working with materials that require higher polymerization temperatures.\u003c\/p\u003e\n      \u003cp\u003eWhen combined with stable operating pressure, precise temperature adjustment helps technicians follow advanced resin processing protocols more accurately. This additional capacity can be particularly useful for laboratories that handle a wide range of dental resins and wish to avoid being restricted by a lower maximum operating temperature.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eWhat are the benefits of additional temperature capacity?\u003c\/strong\u003e\u003c\/summary\u003e\n      \u003cp\u003eAdditional temperature capacity provides greater operating flexibility within the dental laboratory. Although not every application requires 120 °C, having access to this temperature allows technicians to accommodate a wider variety of polymerization protocols.\u003c\/p\u003e\n      \u003cp\u003eConventional dental resins can be processed at lower temperatures, while the higher temperature range remains available when required by the material manufacturer. This versatility allows a broader selection of pressure polymerization procedures to be performed using a single piece of equipment.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eIs the Polymax 1 120 °C suitable for dental laboratories using different resin systems?\u003c\/strong\u003e\u003c\/summary\u003e\n      \u003cp\u003eYes. This is one of the main advantages of the \u003cstrong\u003ePolymax 1 120 °C\u003c\/strong\u003e. It is suitable for dental laboratories working with heat-curing resins, self-curing resins, denture repairs, denture bases, relining materials and specialised resins requiring controlled processing conditions.\u003c\/p\u003e\n      \u003cp\u003eIts adjustable temperature settings allow dental technicians to select the appropriate cycle for each material. Operating pressure helps reduce porosity and improve resin density, provided that the processing parameters follow the manufacturer's recommendations for the intended application.\u003c\/p\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails class=\"mdp-faq-item\"\u003e\n      \u003csummary\u003e\u003cstrong\u003eHow should the Polymax 1 120 °C be maintained to ensure consistent pressure?\u003c\/strong\u003e\u003c\/summary\u003e\n      \u003cp\u003eRoutine maintenance primarily involves checking the lid gasket, polymerization chamber, water level and compressed air supply. The sealing gasket must remain clean, flexible and correctly lubricated to maintain effective pressure sealing throughout the polymerization cycle.\u003c\/p\u003e\n      \u003cp\u003eThe chamber should be cleaned regularly using gentle methods and products compatible with the equipment materials. Clean or demineralised water may help reduce mineral deposits and contribute to the reliable operation of the pressure polymerizer over time.\u003c\/p\u003e\n    \u003c\/details\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c!-- CHAPTER 17 — CONCLUSION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n  \u003cdiv class=\"mdp-card mdp-soft\"\u003e\n    \u003ch2\u003e\u003cstrong\u003eA High-Temperature Dental Pressure Polymerizer for Greater Laboratory Versatility\u003c\/strong\u003e\u003c\/h2\u003e\n\n    \u003cp\u003eThe \u003cstrong\u003eDreve Polymax 1 120 °C\u003c\/strong\u003e is a professional pressure polymerization solution for dental laboratories seeking equipment capable of performing both conventional and advanced dental resin curing cycles.\u003c\/p\u003e\n\n    \u003cp\u003eIts continuously adjustable temperature of up to 120 °C, operating pressure of 3 to 4.2 bar, 2.2-litre chamber, timer of up to 90 minutes and robust construction make it suitable for technical dental resins, denture repairs, removable prostheses and applications requiring accurate control of polymerization conditions.\u003c\/p\u003e\n\n    \u003cp\u003eFor dental laboratories seeking greater thermal flexibility, improved control over curing procedures and the ability to process more demanding materials, the \u003cstrong\u003eDreve Polymax 1 120 °C\u003c\/strong\u003e offers a reliable and durable solution that integrates easily into everyday dental laboratory workflows.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"Dreve","offers":[{"title":"Silver","offer_id":46603748376911,"sku":"34281","price":3150.0,"currency_code":"EUR","in_stock":true},{"title":"Red","offer_id":46603748409679,"sku":"3428","price":3150.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/polymerisateur-polymax-dreve-120_-c.jpg?v=1761858671","url":"https:\/\/www.massiliadental.com\/en\/products\/dreve-polymax-1-dental-pressure-polymerizer-120c","provider":"Massilia Dental - Fournitures Matériel Dentaire","version":"1.0","type":"link"}