{"product_id":"dents-cross-linked-anterieure-bas-forme-i4","title":"Polident Cross Linked 2 lower anterior denture teeth – I4 mould – VITA* shades","description":"\u003c!-- MASSILIA DENTAL STUDIO | DESIGN: MILA PREMIUM 2026 | VERSION: MDP v1.0 | PRODUCT: Polident Cross Linked 2 Lower Anterior Denture Teeth I1 --\u003e\n\u003cdiv id=\"md-product\" class=\"md-product mdp-product mila-premium-2026\"\u003e\n\u003c!-- CHAPTER 1 — PRODUCT HERO --\u003e\n\u003csection class=\"mdp-section mdp-hero\"\u003e\n\u003cdiv class=\"mdp-card mdp-visual\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/dents-cross-i4-polident.jpg?v=1788968221\" alt=\"Polident Cross Linked 2 I1 lower anterior denture teeth, set of 6 cross-linked PMMA acrylic teeth for removable dental prostheses\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"mdp-card mdp-hero-content\"\u003e\n\u003cdiv class=\"mdp-badges\"\u003e\n\u003cspan class=\"mdp-chip\"\u003eBrand: Polident\u003c\/span\u003e \u003cspan class=\"mdp-chip\"\u003eCross Linked 2\u003c\/span\u003e \u003cspan class=\"mdp-chip\"\u003eLower Anterior I4\u003c\/span\u003e\u0026nbsp;\u003cspan class=\"mdp-chip\"\u003eCross-linked PMMA\u003c\/span\u003e \u003cspan class=\"mdp-chip\"\u003e2-layer construction\u003c\/span\u003e \u003cspan class=\"mdp-chip\"\u003eSet of 6 teeth\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003ePolident Cross Linked 2 Denture Teeth – Lower Anterior I4 Mould\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePolident Cross Linked 2 I4 denture teeth\u003c\/strong\u003e are lower anterior artificial teeth manufactured from \u003cstrong\u003ecross-linked PMMA acrylic resin\u003c\/strong\u003e, designed for the fabrication of complete and partial removable dentures.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eI4 mould\u003c\/strong\u003e is supplied as a \u003cstrong\u003eset of 6 mandibular anterior teeth\u003c\/strong\u003e. Its compact morphology makes it particularly suitable for denture setups requiring controlled tooth proportions, consistent aesthetics and straightforward integration into an acrylic denture base.\u003c\/p\u003e\n\u003cdiv class=\"mdp-mini-grid\"\u003e\n\u003cdiv class=\"mdp-mini-card\"\u003e\n\u003cstrong\u003eI4\u003c\/strong\u003e\u0026nbsp;Compact mandibular anterior mould\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-mini-card\"\u003e\n\u003cstrong\u003e6 teeth\u003c\/strong\u003e Lower anterior tooth set\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-mini-card\"\u003e\n\u003cstrong\u003e34.0 mm\u003c\/strong\u003e Primary mould dimension reference\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-mini-card\"\u003e\n\u003cstrong\u003ePOLA1I4\u003c\/strong\u003e\u0026nbsp;Product reference\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 2 — PRODUCT INTRODUCTION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card mdp-soft\"\u003e\n\u003ch2\u003e\u003cstrong\u003eReliable Lower Anterior Denture Teeth for Everyday Laboratory Work\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCross Linked 2 I4\u003c\/strong\u003e\u0026nbsp;is designed for dental laboratories seeking consistent, easy-to-handle lower anterior acrylic teeth for removable prosthodontic applications.\u003c\/p\u003e\n\u003cp\u003eManufactured from \u003cstrong\u003ecross-linked polymethyl methacrylate (PMMA)\u003c\/strong\u003e, these artificial teeth offer good shade stability, mechanical properties suitable for denture applications and reliable bonding to the denture base resin when the ridge-lap surface is correctly prepared.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eI4 mould\u003c\/strong\u003e is especially useful when mandibular anterior space is limited or when the tooth arrangement requires a compact, discreet and harmonious appearance without compromising positioning accuracy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 3 — APPLICATIONS AND ADVANTAGES --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eRecommended Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003ePolident Cross Linked 2 lower anterior teeth are intended for removable prosthodontic restorations fabricated in professional dental laboratories.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMandibular complete dentures.\u003c\/li\u003e\n\u003cli\u003eRemovable partial dentures.\u003c\/li\u003e\n\u003cli\u003eLower anterior tooth arrangements.\u003c\/li\u003e\n\u003cli\u003eDefinitive acrylic denture restorations.\u003c\/li\u003e\n\u003cli\u003eRepair or replacement of mandibular anterior denture teeth.\u003c\/li\u003e\n\u003cli\u003eCases requiring compact artificial teeth with straightforward positioning.\u003c\/li\u003e\n\u003cli\u003eCost-effective denture fabrication with consistent aesthetic results.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eAdvantages for Dental Laboratories\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe I4 mould combines straightforward tooth selection, efficient arrangement and material properties suited to removable denture fabrication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact tooth morphology\u003c\/strong\u003e for narrow mandibular anterior arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-linked PMMA\u003c\/strong\u003e for reliable performance under normal denture service conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-layer acrylic construction\u003c\/strong\u003e for consistent aesthetic appearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable bonding\u003c\/strong\u003e when the ridge-lap surface is roughened and treated with MMA monomer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable tooth surfaces\u003c\/strong\u003e allowing controlled grinding, finishing and repolishing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet of 6 teeth\u003c\/strong\u003e for convenient mandibular anterior tooth arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple shade options\u003c\/strong\u003e according to available product variants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 4 — I1 MOULD POSITIONING --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eI4 Mould: Compact Morphology and Consistent Lower Anterior Aesthetics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eIn the mandibular anterior region, tooth mould selection directly influences smile aesthetics, phonetics, the relationship with opposing teeth and the overall harmony of the denture arrangement.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eI4 mould\u003c\/strong\u003e is designed for cases requiring compact lower anterior denture teeth, particularly when available space is limited or when a subtle mandibular incisal arrangement is preferred.\u003c\/p\u003e\n\u003cp\u003eIt supports the fabrication of functional and aesthetically balanced tooth arrangements while maintaining the straightforward laboratory handling associated with the Cross Linked 2 range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 5 — MATERIAL FEATURES --\u003e\n\u003csection class=\"mdp-section mdp-grid-3\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eTwo-Layer Construction\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe two-layer acrylic construction provides a consistent aesthetic appearance suited to everyday removable prosthodontic restorations and mandibular anterior tooth arrangements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eCross-Linked PMMA\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eCross-linked polymethyl methacrylate contributes to colour stability, thermal stability and resistance to mechanical stresses encountered during normal denture use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003ePrepared Bonding Surface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe ridge-lap surface should be roughened or abraded and subsequently wetted with dental MMA monomer to optimise bonding to the acrylic denture base resin.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 6 — I1 MORPHOLOGY --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card mdp-soft\"\u003e\n\u003ch2\u003e\u003cstrong\u003eI4 Morphology: Compact Lower Anterior Teeth for Precise Positioning\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eI4 mould\u003c\/strong\u003e belongs to the Cross Linked 2 mandibular anterior tooth range. It is intended for denture arrangements requiring discreet, proportionate artificial teeth that are compatible with smaller mandibular arches.\u003c\/p\u003e\n\u003cp\u003eAccording to the Polident tooth mould chart, the dimensional references for the I4 mould are \u003cstrong\u003e34.0 \/ 9.1 \/ 5.0 mm\u003c\/strong\u003e. These measurements should be interpreted in conjunction with the manufacturer's mould chart and the selected denture arrangement.\u003c\/p\u003e\n\u003cp\u003eFinal mould selection should consider the available prosthetic space, mandibular incisor positioning, opposing maxillary tooth arrangement, intermaxillary relationship and desired aesthetic outcome.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 7 — PARTIAL AND COMPLETE DENTURE APPLICATIONS --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eRemovable Partial Dentures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe I4 mould can be used to replace or supplement mandibular incisors in removable partial dentures, particularly when anterior prosthetic space is restricted.\u003c\/p\u003e\n\u003cp\u003eIts compact morphology facilitates integration with the remaining natural dentition, provided that appropriate shade matching and functional adjustments are performed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eComplete Dentures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eIn complete denture fabrication, the I4 mould helps establish a regular, discreet mandibular incisal line that harmonises with the maxillary tooth arrangement.\u003c\/p\u003e\n\u003cp\u003eTooth selection should be guided by the vertical dimension of occlusion, intermaxillary relationship, facial aesthetics and the selected occlusal scheme.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 8 — I1 MOULD SELECTION GUIDE --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eWhen Should You Choose the I4 Mould?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe I1 mould is particularly suitable when the dental laboratory requires compact lower anterior teeth that are easy to arrange within limited mandibular prosthetic space.\u003c\/p\u003e\n\u003cdiv class=\"mdp-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLaboratory Situation\u003c\/th\u003e\n\u003cth\u003eAdvantages of the I4 Mould\u003c\/th\u003e\n\u003cth\u003eKey Considerations\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimited mandibular anterior space\u003c\/td\u003e\n\u003ctd\u003eCompact morphology for easier integration\u003c\/td\u003e\n\u003ctd\u003eCheck the available mandibular intercanine width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubtle mandibular tooth arrangement\u003c\/td\u003e\n\u003ctd\u003eRegular and discreet incisal line\u003c\/td\u003e\n\u003ctd\u003eVerify harmony with the maxillary tooth arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable partial denture\u003c\/td\u003e\n\u003ctd\u003eTargeted replacement of lower anterior teeth\u003c\/td\u003e\n\u003ctd\u003eMatch the shade to the remaining natural teeth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete denture\u003c\/td\u003e\n\u003ctd\u003eSimple and reproducible tooth arrangement\u003c\/td\u003e\n\u003ctd\u003eConfirm vertical dimension and occlusal relationships\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDenture repair\u003c\/td\u003e\n\u003ctd\u003eConvenient tooth set for anterior replacement\u003c\/td\u003e\n\u003ctd\u003ePrepare the ridge-lap surface and denture base before polymerisation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 9 — RIDGE-LAP PREPARATION AND TOOTH ARRANGEMENT --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eRidge-Lap Preparation: Optimising Bonding to the Denture Base\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe bond between acrylic denture teeth and the denture base resin is strongly influenced by mechanical surface preparation before polymerisation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoughen or abrade the ridge-lap and cervical bonding surfaces of the teeth.\u003c\/li\u003e\n\u003cli\u003eEnsure that the bonding surfaces are clean, textured and free from contamination.\u003c\/li\u003e\n\u003cli\u003eApply dental MMA monomer to the tooth bonding surface and denture base contact area using a brush.\u003c\/li\u003e\n\u003cli\u003eRemove all traces of wax, separating agent, grease and grinding debris.\u003c\/li\u003e\n\u003cli\u003eIntroduce controlled mechanical retention grooves when required.\u003c\/li\u003e\n\u003cli\u003eFollow the processing instructions supplied with the selected denture base resin.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eLower Anterior Tooth Arrangement: Practical Laboratory Guidelines\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe I4 mould should be positioned accurately to achieve a natural incisal line, appropriate phonetics and balanced occlusal relationships.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the mandibular intercanine width.\u003c\/li\u003e\n\u003cli\u003eCheck the long-axis inclination of the lower incisors.\u003c\/li\u003e\n\u003cli\u003eAdjust the visible crown height in relation to the maxillary tooth arrangement.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive reduction of the incisal edges.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient acrylic material at the ridge-lap surface.\u003c\/li\u003e\n\u003cli\u003eRepolish all adjusted surfaces after grinding and finishing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 10 — DENTAL LABORATORY WORKFLOW --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eRecommended Dental Laboratory Workflow\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eCross Linked 2 I4 denture teeth can be incorporated into a conventional removable denture fabrication workflow involving tooth arrangement, wax try-in, flasking, polymerisation and final finishing.\u003c\/p\u003e\n\u003cdiv class=\"mdp-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStage\u003c\/th\u003e\n\u003cth\u003eLaboratory Procedure\u003c\/th\u003e\n\u003cth\u003eObjective\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1. Selection\u003c\/td\u003e\n\u003ctd\u003eSelect the I4 mould and the appropriate available shade\u003c\/td\u003e\n\u003ctd\u003eMatch the artificial teeth to the clinical requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2. Aesthetic assessment\u003c\/td\u003e\n\u003ctd\u003eEvaluate the smile, remaining natural teeth, maxillary arrangement and mandibular space\u003c\/td\u003e\n\u003ctd\u003eAchieve a harmonious anterior appearance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3. Wax setup\u003c\/td\u003e\n\u003ctd\u003ePosition the teeth according to the incisal line and intermaxillary relationship\u003c\/td\u003e\n\u003ctd\u003eEstablish a functional and aesthetically balanced arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4. Try-in\u003c\/td\u003e\n\u003ctd\u003eAssess aesthetics, phonetics, lip support and occlusion\u003c\/td\u003e\n\u003ctd\u003eValidate the arrangement before processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5. Ridge-lap preparation\u003c\/td\u003e\n\u003ctd\u003eAbrade, clean and apply dental MMA monomer\u003c\/td\u003e\n\u003ctd\u003ePromote bonding to the denture base resin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6. Polymerisation\u003c\/td\u003e\n\u003ctd\u003eFollow the denture base resin manufacturer's processing instructions\u003c\/td\u003e\n\u003ctd\u003eAchieve a stable and durable tooth-to-base bond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7. Adjustment\u003c\/td\u003e\n\u003ctd\u003eCarefully adjust occlusal contacts\u003c\/td\u003e\n\u003ctd\u003eMinimise excessive loading and occlusal interferences\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8. Finishing\u003c\/td\u003e\n\u003ctd\u003eRepolish adjusted surfaces and clean the completed denture\u003c\/td\u003e\n\u003ctd\u003eMaintain comfort, hygiene and aesthetics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 11 — AVAILABLE SHADES --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eAvailable Shades\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe I4 mould is offered in several shades, subject to available product variants. Shade selection should take into account the overall denture arrangement, remaining natural teeth and aesthetic requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA1, A2, A3, A3.5, A4.\u003c\/li\u003e\n\u003cli\u003eB1, B2, B3.\u003c\/li\u003e\n\u003cli\u003eC2, C3.\u003c\/li\u003e\n\u003cli\u003eD2, D3, D4.\u003c\/li\u003e\n\u003cli\u003eAvailability depends on stock levels and the selected product variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eShade Selection for Lower Anterior Teeth\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe mandibular anterior region should maintain aesthetic harmony with the maxillary teeth, any remaining natural dentition and the patient's overall dental appearance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAssess the shade under suitable lighting conditions.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive contrast with the maxillary tooth arrangement.\u003c\/li\u003e\n\u003cli\u003eAdjust brightness and value according to the aesthetic requirements.\u003c\/li\u003e\n\u003cli\u003eConsider the shade of the remaining natural teeth.\u003c\/li\u003e\n\u003cli\u003eCheck shade consistency between lower anterior and posterior denture teeth.\u003c\/li\u003e\n\u003cli\u003eConfirm the availability of the selected shade before processing the case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 12 — AESTHETICS AND FUNCTION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card mdp-soft\"\u003e\n\u003ch2\u003e\u003cstrong\u003eLower Anterior Aesthetics: Compact Tooth Morphology with a Significant Functional Role\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAlthough mandibular anterior teeth may appear less prominent, they contribute significantly to the overall balance of a removable denture. They influence the smile line, the relationship with the maxillary incisors and the natural appearance of the completed tooth arrangement.\u003c\/p\u003e\n\u003cp\u003eThe I4 mould provides compact tooth proportions, particularly useful when the mandibular anterior segment must remain discreet and should not appear excessively bulky or prominent.\u003c\/p\u003e\n\u003cp\u003eOnce the tooth positions have been validated, adjustments should remain conservative to preserve the incisal morphology, tooth axes and overall aesthetic harmony.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 13 — DURABILITY AND FINISHING --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eDurability, Adjustment and Finishing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe cross-linked PMMA formulation of Cross Linked 2 denture teeth provides good performance during everyday use while allowing controlled laboratory adjustments to occlusion, tooth morphology and denture base adaptation.\u003c\/p\u003e\n\u003cdiv class=\"mdp-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProcedure\u003c\/th\u003e\n\u003cth\u003eObjective\u003c\/th\u003e\n\u003cth\u003ePrecaution\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRidge-lap surface roughening\u003c\/td\u003e\n\u003ctd\u003ePrepare the tooth surface for bonding to acrylic resin\u003c\/td\u003e\n\u003ctd\u003eAvoid weakening the tooth through excessive material removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlled retention grooves\u003c\/td\u003e\n\u003ctd\u003eImprove mechanical retention when required\u003c\/td\u003e\n\u003ctd\u003eMaintain sufficient material thickness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncisal adjustment\u003c\/td\u003e\n\u003ctd\u003eRefine the anterior incisal arrangement\u003c\/td\u003e\n\u003ctd\u003eMinimise visually noticeable modifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOcclusal equilibration\u003c\/td\u003e\n\u003ctd\u003eReduce unwanted occlusal interferences\u003c\/td\u003e\n\u003ctd\u003eWork progressively and check contacts regularly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal polishing\u003c\/td\u003e\n\u003ctd\u003eRestore surface smoothness and patient comfort\u003c\/td\u003e\n\u003ctd\u003eAvoid excessive heat generation in the PMMA material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 14 — SAFETY, STORAGE AND TRACEABILITY --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eSafety and Handling Precautions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eSafety precautions primarily concern the mechanical processing of PMMA in the dental laboratory, particularly during grinding, surface roughening and retention groove preparation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWear protective eyewear during grinding and abrasion procedures.\u003c\/li\u003e\n\u003cli\u003eUse effective local dust extraction at the workstation.\u003c\/li\u003e\n\u003cli\u003eAvoid inhalation of PMMA grinding dust.\u003c\/li\u003e\n\u003cli\u003eApply light pressure during grinding to minimise heat generation.\u003c\/li\u003e\n\u003cli\u003eAvoid use in cases of known hypersensitivity to acrylic materials.\u003c\/li\u003e\n\u003cli\u003eFollow the laboratory's established health and safety procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eStorage and Traceability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eProper organisation of artificial tooth sets helps prevent shade, mould and batch identification errors during denture fabrication.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKeep the teeth in their original packaging until required.\u003c\/li\u003e\n\u003cli\u003eClearly identify the I4 mould, shade and batch number.\u003c\/li\u003e\n\u003cli\u003ePrevent contamination by wax, separating agents or grinding dust.\u003c\/li\u003e\n\u003cli\u003eRetain batch information for material traceability.\u003c\/li\u003e\n\u003cli\u003eVerify the selected shade before final tooth arrangement.\u003c\/li\u003e\n\u003cli\u003eFor professional dental laboratory use only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 15 — POLIDENT TECHNICAL DOCUMENTATION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003ePolident Technical Documentation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003ePolident technical documents provide additional information regarding product ranges, available tooth moulds, instructions for use and material safety data.\u003c\/p\u003e\n\u003cdiv class=\"mdp-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDocument\u003c\/th\u003e\n\u003cth\u003eLaboratory Reference\u003c\/th\u003e\n\u003cth\u003eLink\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCross Linked 2 Tooth Mould Chart\u003c\/td\u003e\n\u003ctd\u003eIdentify anterior and posterior moulds, tooth combinations and dimensional references.\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.polident.si\/mma_bin.php?id=2026031707570116\u0026amp;view=download\"\u003e\u003cstrong\u003eDownload Tooth Mould Chart\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Data Sheet\u003c\/td\u003e\n\u003ctd\u003eConsult the Polident safety data sheet for Primodent and Cross Linked 2 artificial teeth.\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.polident.si\/mma_bin.php?id=2023040614410339\"\u003e\u003cstrong\u003eDownload Polident Safety Data Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 16 — TECHNICAL SPECIFICATIONS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eMain Technical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"mdp-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003ctd\u003eCross Linked 2 Lower Anterior Denture Teeth I1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003ePolident\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Reference\u003c\/th\u003e\n\u003ctd\u003ePOLA1I4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Range\u003c\/th\u003e\n\u003ctd\u003eCross Linked 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eLower anterior acrylic denture teeth for removable dental prostheses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMould\u003c\/th\u003e\n\u003ctd\u003eI4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDental Arch\u003c\/th\u003e\n\u003ctd\u003eMandibular \/ Lower anterior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackaging\u003c\/th\u003e\n\u003ctd\u003e1 set of 6 anterior denture teeth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eCross-linked PMMA, pigmented polymethyl methacrylate-based polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConstruction\u003c\/th\u003e\n\u003ctd\u003e2-layer acrylic construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI4 Mould Dimensional References\u003c\/th\u003e\n\u003ctd\u003e34.0 \/ 9.1 \/ 5.0 mm according to the Polident tooth mould chart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIndications\u003c\/th\u003e\n\u003ctd\u003eComplete and partial removable dentures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial Properties\u003c\/th\u003e\n\u003ctd\u003eColour stability, thermal stability, abrasion resistance and solvent resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBonding to Denture Base\u003c\/th\u003e\n\u003ctd\u003eRoughen or abrade the ridge-lap surface and apply dental MMA monomer before polymerisation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAvailable Shades\u003c\/th\u003e\n\u003ctd\u003eA1, A2, A3, A3.5, A4, B1, B2, B3, C2, C3, D2, D3, D4, subject to available variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturing\u003c\/th\u003e\n\u003ctd\u003eDeveloped, manufactured and quality-controlled in Slovenia, European Union\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntended Users\u003c\/th\u003e\n\u003ctd\u003eProfessional dental laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 17 — COMMON MISTAKES TO AVOID --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eCommon Mistakes to Avoid When Using the I1 Mould\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"mdp-table-wrap\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCommon Mistake\u003c\/th\u003e\n\u003cth\u003ePotential Consequence\u003c\/th\u003e\n\u003cth\u003eRecommended Practice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelecting I4 without checking available space\u003c\/td\u003e\n\u003ctd\u003eOvercrowded or poorly balanced tooth arrangement\u003c\/td\u003e\n\u003ctd\u003eVerify the mandibular intercanine width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsufficient ridge-lap preparation\u003c\/td\u003e\n\u003ctd\u003eReduced bonding reliability to the acrylic denture base\u003c\/td\u003e\n\u003ctd\u003eRoughen, abrade or prepare retention grooves before polymerisation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmitting MMA surface treatment\u003c\/td\u003e\n\u003ctd\u003eLess effective chemical bonding\u003c\/td\u003e\n\u003ctd\u003eApply dental MMA monomer to the tooth and denture base contact surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContaminating bonding surfaces\u003c\/td\u003e\n\u003ctd\u003eIncreased risk of debonding or inconsistent retention\u003c\/td\u003e\n\u003ctd\u003eRemove wax, separating agents, grease and grinding debris\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcessive incisal edge reduction\u003c\/td\u003e\n\u003ctd\u003eLoss of aesthetic harmony\u003c\/td\u003e\n\u003ctd\u003eAdjust gradually and repolish the modified surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIgnoring the opposing maxillary arrangement\u003c\/td\u003e\n\u003ctd\u003eUnbalanced occlusal contacts or compromised aesthetics\u003c\/td\u003e\n\u003ctd\u003eVerify occlusion and the opposing incisal relationship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrinding without dust extraction\u003c\/td\u003e\n\u003ctd\u003eUnnecessary exposure to PMMA dust\u003c\/td\u003e\n\u003ctd\u003eUse local dust extraction and protective eyewear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 18 — BENEFITS FOR DENTAL TECHNICIANS AND PATIENTS --\u003e\n\u003csection class=\"mdp-section mdp-grid-2\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eWhy Dental Technicians Choose the I4 Mould\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe I4 mould meets the requirements of lower anterior denture arrangements where precision, discreet tooth proportions and straightforward laboratory processing are essential.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompact morphology for restricted mandibular anterior spaces.\u003c\/li\u003e\n\u003cli\u003eSimple and reproducible tooth arrangement.\u003c\/li\u003e\n\u003cli\u003eConsistent aesthetics in the lower anterior region.\u003c\/li\u003e\n\u003cli\u003eAllows controlled adjustments followed by appropriate repolishing.\u003c\/li\u003e\n\u003cli\u003eGood compatibility with acrylic denture base resins.\u003c\/li\u003e\n\u003cli\u003eConvenient tooth sets for shade-based laboratory organisation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eBenefits for the Denture Patient\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAppropriately selected mandibular anterior denture teeth contribute to smile harmony, functional comfort and the overall balance of the removable prosthesis.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMore natural mandibular incisal appearance.\u003c\/li\u003e\n\u003cli\u003eDiscreet tooth proportions suited to limited prosthetic space.\u003c\/li\u003e\n\u003cli\u003eShade selection compatible with remaining natural teeth.\u003c\/li\u003e\n\u003cli\u003eImproved arrangement balance when the mould is correctly selected.\u003c\/li\u003e\n\u003cli\u003ePossibility of laboratory repair or tooth replacement.\u003c\/li\u003e\n\u003cli\u003eReliable solution for everyday removable denture applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 19 — RECOMMENDED COMPLEMENTARY PRODUCTS --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eRecommended Complementary Products\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"mdp-grid-3\"\u003e\n\u003carticle class=\"mdp-card mdp-related-card\"\u003e\u003ca href=\"https:\/\/www.massiliadental.com\/en\/collections\/cold-cure-resin-definitive-dentures\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/kit-triplex-cold.jpg?v=1773827430\" alt=\"Cold-curing acrylic resin for denture fabrication and repair\" loading=\"lazy\"\u003e\n\u003ch3\u003e\u003cstrong\u003eCold-Curing Acrylic Resins\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/a\u003e\u003c\/article\u003e\n\u003carticle class=\"mdp-card mdp-related-card\"\u003e\u003ca href=\"https:\/\/www.massiliadental.com\/en\/collections\/polishing-brushes-for-acrylic-resins-or-metals-polishing-lathe\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/brosse-a-polir-utg-42100m60x4l-noire.jpg?v=1785331007\" alt=\"Dental laboratory polishing brushes for acrylic denture resins and removable prostheses\" loading=\"lazy\"\u003e\n\u003ch3\u003e\u003cstrong\u003eDental Laboratory Polishing Brushes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/a\u003e\u003c\/article\u003e\n\u003carticle class=\"mdp-card mdp-related-card\"\u003e\u003ca href=\"https:\/\/www.massiliadental.com\/en\/collections\/pumice-polishing-paste-acrylic-resin-metal-dental-laboratory\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/ponce-fine-hinrichs.jpg?v=1781821171\" alt=\"Dental laboratory pumice and polishing compounds for acrylic denture finishing\" loading=\"lazy\"\u003e\n\u003ch3\u003e\u003cstrong\u003ePumice and Polishing Compounds\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/a\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 20 — DELIVERY --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eDelivery and Package Contents\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eSupplied as \u003cstrong\u003e1 set of Polident Cross Linked 2 I4 lower anterior denture teeth\u003c\/strong\u003e, containing \u003cstrong\u003e6 artificial teeth\u003c\/strong\u003e, in the selected shade subject to availability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 21 — FAQ --\u003e\n\u003csection class=\"mdp-section mdp-faq\"\u003e\n\u003cdiv class=\"mdp-card\"\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ – Polident Cross Linked 2 Lower Anterior Denture Teeth I4\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is the I4 mould used for?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe I4 mould is designed for mandibular anterior tooth arrangements in complete and partial removable dentures.\u003c\/p\u003e\n\u003cp\u003eIt is particularly suitable when the dental laboratory requires compact, discreet and easy-to-position artificial teeth for the lower anterior region.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eHow are the I4 denture teeth supplied?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe I4 mould is supplied as \u003cstrong\u003eone set of 6 lower anterior denture teeth\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe shade corresponds to the product variant selected when placing the order.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat are the dimensions of the I4 mould?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe Polident tooth mould chart specifies dimensional references of \u003cstrong\u003e34.0 \/ 9.1 \/ 5.0 mm\u003c\/strong\u003e for the I4 mould.\u003c\/p\u003e\n\u003cp\u003eThese measurements should be interpreted using the manufacturer's mould chart and assessed according to the requirements of the individual denture arrangement.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat material is used to manufacture Cross Linked 2 denture teeth?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eCross Linked 2 artificial teeth are manufactured from \u003cstrong\u003ecross-linked PMMA\u003c\/strong\u003e, an acrylic polymer used in the production of artificial teeth for removable dental prostheses.\u003c\/p\u003e\n\u003cp\u003eThis material provides good stability, resistance under normal service conditions and compatibility with acrylic denture base resins.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eHow can bonding to the denture base resin be improved?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eThe ridge-lap surface should be roughened or abraded before denture base polymerisation.\u003c\/p\u003e\n\u003cp\u003eApplying \u003cstrong\u003edental MMA monomer\u003c\/strong\u003e with a brush to the tooth bonding surface and denture base contact area is recommended to optimise adhesion.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eCan the I4 mould be used in complete dentures?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. The I4 mould can be used in complete denture fabrication when its width, height and mandibular anterior morphology are appropriate for the clinical case.\u003c\/p\u003e\n\u003cp\u003eSelection should be validated in relation to the maxillary tooth arrangement, vertical dimension of occlusion and overall occlusal scheme.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eCan the I4 mould be used in removable partial dentures?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. The I4 mould can be used to replace or supplement mandibular anterior teeth in removable partial dentures.\u003c\/p\u003e\n\u003cp\u003eThe selected mould and shade should be harmonised with the remaining natural dentition to achieve an appropriate aesthetic result.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eCan I4 denture teeth be adjusted in the dental laboratory?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eYes. The teeth can be carefully adjusted, particularly at the ridge-lap surface or incisal edge.\u003c\/p\u003e\n\u003cp\u003eAfter adjustment, all modified surfaces should be repolished to restore an appropriate surface finish.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat precautions should be taken during grinding?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eEffective local dust extraction and protective eyewear are recommended when grinding or adjusting acrylic denture teeth.\u003c\/p\u003e\n\u003cp\u003eGrinding should be performed progressively with controlled pressure to minimise heat generation and preserve the original tooth morphology.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eCan these teeth be used in patients with known acrylic allergies?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eNo. Use should be avoided in cases of known allergy or hypersensitivity to acrylic materials.\u003c\/p\u003e\n\u003cp\u003eThe selection of prosthetic materials should always be appropriate to the patient's clinical circumstances.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"mdp-faq-item\" open=\"\"\u003e\n\u003csummary\u003e\u003cstrong\u003eWhat is included in the delivery?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003eEach order includes \u003cstrong\u003eone set of 6 Polident Cross Linked 2 I4 lower anterior denture teeth\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe required shade must be selected from the available product variants.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- CHAPTER 22 — CONCLUSION --\u003e\n\u003csection class=\"mdp-section\"\u003e\n\u003cdiv class=\"mdp-card mdp-soft\"\u003e\n\u003ch2\u003e\u003cstrong\u003eCross Linked 2 I4: Compact Lower Anterior Acrylic Teeth for Removable Dentures\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePolident Cross Linked 2 Lower Anterior I4 Denture Teeth\u003c\/strong\u003e provide a reliable solution for dental laboratories requiring compact, stable and easy-to-integrate mandibular anterior artificial teeth.\u003c\/p\u003e\n\u003cp\u003eSupplied as a \u003cstrong\u003eset of 6 teeth\u003c\/strong\u003e, the I4 mould combines cross-linked PMMA with a two-layer acrylic construction, supporting the fabrication of discreet, consistent and functional mandibular anterior tooth arrangements.\u003c\/p\u003e\n\u003cp\u003eWhen correctly selected, prepared and processed, the I4 mould contributes to professional prosthodontic results through controlled aesthetics, reliable bonding to the acrylic denture base and consistent finishing quality in everyday dental laboratory applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Proclinic","offers":[{"title":"Bleach 3","offer_id":59426642886991,"sku":"POLBL3I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"A1","offer_id":46555920367951,"sku":"POLA1I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"A2","offer_id":46555920400719,"sku":"POLA2I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"A3","offer_id":46555920433487,"sku":"POLA3I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"A3.5","offer_id":46555920466255,"sku":"POLA3.5I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"A4","offer_id":46555920499023,"sku":"POLA4I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"B1","offer_id":47942723141967,"sku":"POLB1I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"B2","offer_id":46555920531791,"sku":"POLB2I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"B3","offer_id":46555920564559,"sku":"POLB3I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"C2","offer_id":46555920597327,"sku":"POLC2I4","price":5.95,"currency_code":"EUR","in_stock":false},{"title":"C3","offer_id":46555920630095,"sku":"POLC3I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"D2","offer_id":46555920662863,"sku":"POLD2I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"D3","offer_id":46555920695631,"sku":"POLD3I4","price":5.95,"currency_code":"EUR","in_stock":true},{"title":"D4","offer_id":46555920728399,"sku":"POLD4I4","price":5.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0476\/7776\/7838\/files\/cross-I4.jpg?v=1761858426","url":"https:\/\/www.massiliadental.com\/en\/products\/cross-linked-2-lower-anterior-teeth-i4","provider":"Massilia Dental - Fournitures Matériel Dentaire","version":"1.0","type":"link"}